News

Record 16 STA / 16 STA-UL Operating Instructions & Manual

Operating Instructions - Record 16 STA / 16 STA-UL Control Unit

9.1 Controls on STG 16

9.1.1 General

The STG 16 operates with active HIGH level, i.e., a +24 V level must be applied to activate a function. Safety inputs are activated during interruptions. The signal ground (0 V) is connected to protective earth. This connection can be removed for test purposes with the earthing screw at bottom left.

9.1.2 Jumpers

  • J11 (left): For CAN line termination (see AN1).
  • J12 (right): Direction of rotation:
    • Jumper at position 1-2 for D-STA or E-STA-R (factory setting).
    • Jumper at position 2-3 for E-STA-L.
  • J13 (top): Battery monitoring:
    • Jumper at position 1-2 for systems with battery (factory setting).
    • Jumper at position 2-3 for systems without battery.

9.1.3 LED’s (left to right)

  • LED 1 (red) Photocell 1: Lights when obstruction present.
  • LED 2 (red) Photocell 2: Lights when obstruction present.
  • LED 3 (red) Ground: Must light when earthing screw removed (bottom left). Otherwise an earth connection is present.
  • LED 4 (red) Limit switch: Lights up when limit switch is closed.
  • LED 5 (green) +24V: Lights when mains or battery voltage present.
    Caution: In the event of a power failure, processor reset only takes place 1 sec. after this LED extinguishes.
  • LED 6 (green) +35 V: Off for power failure.
  • LED 7 (red): Large control LED right for push-button operation.

9.1.4 Key

This multifunction key has several functions. The selection of function is made with the aid of the neighbouring control LED according to the following table.

Release key while: Function
1st light pulse on LED 7 AKI
2nd light pulse on LED 7 Learn ELS
3rd light pulse on LED 7 Learn door parameters
4th light pulse on LED 7 Configuration mode on
5th light pulse on LED 7 BAT emergency reaction if no mains present
6th light pulse on LED 7 Factory setting for redundancy module
8th light pulse on LED 7 Factory setting of programming and configurations
Press key approx. 13 seconds Hardware reset (new control start)

9.2 Functions of electronic BDE-E

9.2.1 General

The electronic control unit BDE-E is a convenient input and output unit. It contains several virtual control levels. The normal level (1st level) contains the standard modes of operation.

All LED’s light in sequence during the first few seconds after switching on the power supply (run light) and the last operating mode is then displayed.

9.2.2 1st level (operating modes)

9.2.3 Key functions

  • One-way operation
  • Winter mode
  • Automatic mode
  • Continuously open
  • Locked

Programming:

  • Programming decrement
  • Programming increment

A LED indication is assigned to every key, with the exception of the two keys for programming. The LED is off in this level.

  • If the key is pressed again in the „locked“ status, an SSK opening takes place.
  • If the key is pressed again in the „continuously open“ status, manual operation takes place.
  • If the key is pressed for approx. 5 secs. the control is restarted. The programmed data remain stored.

9.2.4 2nd level (control lock)

Entry to this level with key sequence:

The LED lights. The BDE is blocked.

Exit from this level with key sequence:

This releases operation again.

9.2.5 3rd level (programming level)

Entry to this level with key sequence:

  • The LED flashes slowly
  • Selection of following menus by key operation
  • The value is displayed while the key remains pressed

The value display takes place proportionately in max. 40 increments. Divided in 5 LED’s from left to right, with each LED divided into 8 increments. The range from 0% to 100% is thereby covered.

Example: 75% winter opening
  • LED’s fully lit (corresponding to 3 times 8 increments)
  • LED has an on/off ratio of 6/2 (corresponding to 6 increments)
  • LED remains off. Therefore total 30 increments, i.e. 75%.

Menu functions

Function Range Step width Factory setting
Closing speed 3 - 50 cm/s 1,25 cm/s 40 cm/s
Winter opening width * 20 cm - 100% approx. 1 cm steps 62,5%
Door hold-open time 0 - 20 s 0,5 s 1 s
Door hold-open time SSK 0 - 20 s 0,5 s 10 s
Opening speed 3 - 70 cm/s 1,75 cm/s 50 cm/s

* on „continuously open“ the door follows the ONLINE winter opening width

Setting

  • Following menu selection (the LED of the menu selected lights) the value can be changed by pressing the keys several times.
  • The current value is continuously displayed while this key is pressed.
  • At the highest range limit the setting returns to the lowest value and vice-versa.
  • The value is reset to the factory setting by pressing the keys simultaneously.
  • Exit from this level is made by pressing the key briefly or if no operation is made for 3 minutes.

9.3 Functions of mechanical BDE-M

9.3.1 General

The mechanical control unit BDE-M is a simple input unit with a key switch. The key can be withdrawn at any position. Winter operation is possible if required.

9.3.2 Modes of operation

  • One-way operation (or winter)
  • Automatic mode
  • Continuously open
  • Locked

Operating indication

The LED lights when mains or battery voltage is present.

9.3.3 Reset key

This hidden key is operated with a paper clip approx. 25 mm long. A small hole is provided for this purpose at the centre of the record logo.

If this key is pressed for approx. 5 seconds, the control unit starts completely new. The programmed data remain stored.