Technical Specifications & Measurements
Standard measurements and adjustments for the SW100 operator.
Note! Measurement Z must be reduced by 20mm if the lower adapter from kit 1007618 is used.
| Parameter | Value |
|---|---|
| Profile Dimensions | 40 x 60 |
| Adjustment Range | -20 to 130 |
| Standard Values | 48, 68, 98, 118 |
DIN Left Installation Configuration
Reference: ILL-01592
Mounting Steps (DIN Left)
- Identify mounting points (CL1, CL2).
- Secure operator using standard bolt pattern (8x bolts required).
- Align with door leaf.
DIN Right Installation Configuration
Reference: ILL-01667
Mounting Steps (DIN Right)
- Identify mounting points for right-hand configuration.
- Position operator using the centered top bolt first.
- Follow the prescribed bolt pattern for remaining fixtures.
General Mounting & Torque Instructions
Important: Operator should be attached using the top/centered bolt first, then follow the pattern.
Torque Specifications
Tighten fixings to 25 Nm.
Final Adjustments
- Ensure arm system clicks into place ("Click" indication).
- Note! Do not change door stop for PULL application.