Assa Abloy SW100 - Electrical Connection Guide (Pages 43-48)

10. Electrical Connection

General Safety Guidelines

  • Place the electric switch easily accessible from the operator. If a plug contact is used in the installation the wall socket shall be placed easily accessible from the operator.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

10.1 Mains Connection

  1. Switch off the mains.
  2. Assemble the bottom end plates and tighten the two screws firmly.
  3. Connect the plug contact to the wall socket or connect to the mains switch.
    Note! The mains switch must be connected according to national regulation.
  4. Connect the mains to the operator.

Mains Specifications: 100-240V AC – 50/60Hz

Wiring Color Codes & Fuse Info

  • PE (Schutzleiter/Ground): Yellow/Green
  • L (Live): Brown
  • N (Neutral): Blue
  • Fuse: 10AT

Symbol shown to ensure that the manual is read before the installation starts.

10.2 Control Units

10.2.1 CU-ESD

The CU-ESD can be equipped with extension units, EXU-SI and/or EXU-SA, depending on the functions required. (See sections below).

Terminal/Potentiometer Definitions

Label/Function Description
24 V DC Power supply output
GND Ground
Safety Impulse Overhead presence detection / Mat safety
OPD Overhead presence detection (incl. 24V, LOUT and Safety Impulse)
IMP Inner impulse
XIMP / IIMP Impulse inputs (External/Internal)
Lock kick switch Lock kick switch input
Synchronizing Synchronizing of double doors

Potentiometer Settings (Adjustable)

  • Hold open time (1.5s - 30s)
  • Closing torque
  • Power assist
  • Closing speed
  • Opening speed
  • Spring tension

DIP Switch Settings

  • PUSH & GO / PULL (Arm system setting)
  • Learned Button (LRN)
  • Stop on stall (SOS)
  • PAG (Push and Go)
  • MAT (Safety mat)

10.2.2 Arm System Selection

Factory set arm configuration is PUSH. If PULL or ST is required:

  1. Switch power OFF
  2. Select arm configuration (using DIP switches)
  3. Switch power ON
After changing any system selection a new LEARN must be carried out.

10.2.3 Extension Units EXU-SI / EXU-SA

Installation

To extend the functions, the extension units can be mounted on top of the control unit CU-ESD, separately or combined.

Tools required: 5mm nut driver, Torx T10.

10.2.4 Extension Unit EXU-SI

Functions: This extension unit has inputs for electro-mechanical lock, program selector, batteries, KILL function, OPEN/CLOSE, KEY opening and outer impulse.

Terminal Configuration

Terminal label Description
+24 V DC / GND Power Supply
OPEN / EXIT / OFF Program selector inputs
UNL Unlocked signal from lock
KRST KILL reset
KILL KILL impulse
KEY KEY impulse (5s)
O/C OPEN/CLOSE impulse (latching relay)
OIMP Outer impulse
Lock Electro-mechanical locking device (12VDC max 500mA / 24VDC max 250mA)

Key Settings

  • Battery Backup Unit: Battery monitoring.
  • Lock Functions:
    • Locked without power (OFF) / with power (ON)
    • Lock 12V (OFF) / 24V (ON)
    • Lock kick: Position OFF (Smooth closing), Position ON (More powerful closing).
  • Potentiometer: Opening delay (0s - 3s).

Notes:

  • If the switch is set to ON, the LOCK RELEASE is active during the opening delay time set by the potentiometer.
  • For PAIR OF DOORS installations, the LOCK RELEASE works in sequence: First the primary then the secondary.
  • Lock only functions when Program Selector is in OFF or EXIT.
  • If a program selector is not used, a jumper is required from position 3 to position 11.

10.2.5 Extension Unit EXU-SA

This extension unit has inputs for door mounted sensors, which can give presence impulse on approach side and/or presence detection on swing path side. Relay output for error indication or door indication is also integrated.

Functions & Terminals

Terminal Label Description
1-5 (Relay) NO/COM/NC Relay output ("External error indication" or "Open door indication") 24V, 1A.
QTST Sensor monitoring
PDET Presence detection (NC)
PIMP Presence impulse (NC)
GND / 24V Power

Settings

  • Blanking Potentiometer: Adjust to avoid presence detection sensor detecting the wall (Range 45 degrees - fully open/Max).
  • Monitoring Jumpers:
    • No monitoring (both jumpers on).
    • Monitoring of presence detection / presence impulse.

10.3 Sensor Cable Inlet

Reference Article Numbers for parts:

  • Art. No.: 1007567
  • Art. No.: 1015368 (BK/SI)

Dimensions noted: ø 3.7, 12mm, 45mm, 48mm.