General Technical Data - STA20 Automatic Door Systems

Installation Notices

Notice: Load Capacity

Load capacity for lintel installations: The standard guidelines for load capacities on lintel installations can be found in the corresponding chapter of the full manual.

Notice: Carriage Requirements
  • For door weight per wing > 90 kg: 3 carriages required
  • For door weight per wing > 125 kg: 4 carriages required

Basic Specifications

  • Noise emission: < 45 dB
  • Protection class: IP20

Door Opening Speed

Values applicable for max. 75% of authorized door weight.

Opening speed performance by model
Model Series Opening Distance Time
D-STA / D-TSA 0.7 m 1 sec.
E-STA / E-TSA 0.7 m 1.5 sec.

Power Supply Data

Electrical specifications per Product Line
Parameter Product Line 20 Product Line 21 Product Line 22
Standard DUO / RED Standard RED Standard
Mains Voltage 100-240 VAC 100-240 VAC 230 VAC 100-240 VAC 230 VAC
Rated Power 90 W 90 W 85 W 90 W 120 W
Fuse Protection 4 AT 4 AT 3,15 AT 4 AT 3,15 AT
*Standby power consumption: approx. 25 W for all (including sensors, control unit and locking device)