News

ED 100 / ED 250 Glass Door Clamping Rail Mounting Guide


Glass door leaves cannot be drilled like timber or metal doors — so how do you connect the slide channel of an ED 100 or ED 250 swing door operator? The answer is the glass door clamping rail (Glastürschuh): a clamp-on profile that grips the top edge of the glass leaf without any glass machining. This guide summarizes the official mounting instructions (document 059916-45532/17143, 07/2024) step by step.

1. What the glass door clamping rail is for

  • Connects the slide channel of the ED 100 / ED 250 to a glass door leaf — no drilling, no glass cut-outs required
  • Clamps mechanically onto the top of the glass panel
  • Suitable for glass thicknesses of 10–13.5 mm
  • Used in hinge-side (pulling) slide-rail installations on all-glass doors, typical for retail fronts, offices and showrooms

2. Key dimensions at a glance

Dimension Value Meaning
Glass thickness 10–13.5 mm permitted glass panel range for the clamping rail
Hinge-side offset 148 mm reference distance from the hinge edge when positioning the rail
Clearance ≥ 5 mm minimum gap to be observed between the clamping point and the moving slide channel
Clamp adjustments 8.5 mm / 10 mm clamping and alignment dimensions shown in the final-setting diagram
Tool 3 mm hex key (Allen) for the clamping screws

3. Mounting in four steps

Step 1 — Position the profiles

Place the slide channel (1) and the glass door clamping rail (2) onto the top edge of the glass leaf. The clamping rail sits on the glass; the slide channel connects the rail to the operator's slide arm.

Step 2 — Fix the clamping points

Starting at the reference position 148 mm from the hinge edge, tighten the clamping screws with a 3 mm hex key. Work at both clamping points so the rail seats evenly on the glass.

Step 3 — Align at 90°

Turn both clamping elements to their final 90° positions as shown in the diagram. This squares the rail to the glass edge and locks the clamping geometry — check that the rail runs parallel to the top of the glass before final tightening.

Step 4 — Final settings and clearances

Set the final clamping dimensions (8.5 mm / 10 mm) and verify the minimum clearance of ≥ 5 mm between the clamping point and the slide channel's moving carriage. Confirm the glass thickness is within the 10–13.5 mm range before putting the door into service.

Practical tips for installers:
  • Verify the actual glass thickness before ordering — panels outside 10–13.5 mm need a different solution.
  • After mounting, run the operator's learning cycle and check that the slide block passes the clamping area without contact (the ≥ 5 mm rule).
  • On fire-rated or escape-route glass doors, confirm the approved door/operator combination before installation.

Compatible glass door hardware for ED 100 / ED 250

DoorDynamic supplies OEM-compatible glass door clamping rails, slide channels and mounting accessories compatible with the dormakaba ED 100 and ED 250 — dimension-checked against the original specifications, including the 10–13.5 mm glass range and 148 mm hinge offset, with fast shipping to Europe and the Middle East. Send us your glass thickness and door width, and we will confirm the correct configuration.

dormakaba, DORMA and other mentioned brand names are trademarks of their respective owners. DoorDynamic is an independent supplier of compatible parts and is not affiliated with the original manufacturer. All dimensions in this article are taken from the public mounting instructions (059916-45532/17143, 07/2024) and are provided for reference only.

Previous
ED 100 / ED 250 Integrated Emergency Power Supply (UPS)

Leave a Comment

Your email address will not be published.