8 Cleaning and maintenance
8.1 Cleaning
Risk of electric shock due to improper cleaning!
- Doors should only be cleaned by trained personnel.
Danger of injury due to impact and crushing!
- Set the mode of operation to “Off”.
- Secure door leaves against accidental movement before carrying out cleaning work.
- Cleaning should only be carried out by persons who have been instructed in the safety devices.
- Mark the door accordingly during cleaning.
- During cleaning work, secure the system against unauthorised switching of the mode of operation.
| What is to be cleaned | How is it to be cleaned |
|---|---|
| Safety sensor | Wipe with moist cloth. |
| Glass surfaces | Wipe with a suitable glass cleaner and dry. |
| Stainless surfaces | Wipe with non-scratching cloth. |
| Coated surfaces | Wipe with water and soap. |
| Anodised surfaces | Wipe with non-alkaline potassium soap (pH value 5.5...7). |
| Programme switch | Wipe with damp cloth. Do not use a cleaning agent. |
8.2 Maintenance
The owner must ensure that the system is working perfectly. In order to ensure faultless operation, the door system has to be maintained by a service technician when the maintenance indicator lights up.
Slimdrive SL T30 must be permanently ready to use. The operator is responsible for checking its functioning at least once a month.
The maintenance displays are located at the programme switches. The version differs depending on the programme switch used:
| Programme switch | Maintenance indicator |
|---|---|
| Display programme switch | A red dot (17) appears at the bottom right of the display. |
| TPS | “Reduced opening width” LED (18) flashes. |
| MPS, MPS-ST | LED (19) flashes. |
The maintenance display lights up after the specified calendar period or number of opening cycles, depending on what occurs first:
| Door system | Calendar period | Opening cycles |
|---|---|---|
| Standard | 1 year | 500,000 |
| FR variant / RD variant | 1 year | 200,000 |
| T30 variant | ½ year | 200,000 |
8.3 Rechargeable battery
Information regarding the Battery Directive:
(Applicable in Germany and all other countries in the European Union, together with the country's own regulations of a separate old battery-return system.)
In accordance with the Battery Directive, we are obliged to inform you of the following in connection with the sale of batteries or rechargeable batteries respectively in connection with the delivery of devices containing batteries or rechargeable batteries:
Rechargeable batteries and batteries must not be disposed of with household waste. Disposal with household waste is expressly forbidden according to the Battery Directive. As the end-consumer, you are legally obliged to return used batteries. Please dispose of batteries at a municipal collection point or in store. Batteries obtained from us can be returned to us by mail. The address is:
GEZE GmbH, Goods receptionReinhold-Vöster-Str. 21-29
D-71229 Leonberg
Batteries that contain hazardous substances are labelled with the symbol of a crossed-out garbage can. The chemical identifier of the harmful chemical, Cd for cadmium, Pb for lead, Hg for mercury, is located under the garbage can symbol.
Automatic sliding door systems from GEZE contain NiCd rechargeable batteries.
NiCd rechargeable batteries must be replaced after 2 years at the latest.
9 Safety-related inspection by trained professionals
In compliance with:
- DIN 18650-2 “Powered pedestrian doors – Part 2: Safety at powered pedestrian doors”, Section 5 and
- EN 16005 “Power operated pedestrian doorsets”, Chapter 4.2.1
The safe condition of power operated doors must be checked before initial commissioning and once a year by a professional authorised by GEZE.
GEZE offers maintenance contracts with the following services:
- Cleaning and readjustment of roller carriage and tracks
- Inspection and adjustment of toothed belts
- Inspection of door suspension plate and floor guide
- Inspection of fixing elements for firm fit
- Performance of miscellaneous adjustment work
- Performance of operational checks
- Perform function test for SL-RD and SL-T30
- Inspection and functional checks of all safety and control equipment in compliance with the requirements in the test log for power-operated windows, doors and gates; sliding doors and sliding gates BGG 950 (ZH 1/580.2) edition.
10 Technical data
- Opening speed: 0.03 m/s ... 0.8 m/s
- Closing speed: 0.03 m/s ... 0.8 m/s
- Electrical connection values: 230 V; 50 Hz according to DIN IEC 60038
- Connected load: max. 300 VA (Powerdrive PL: max. 450 VA)
- Fuse protection: Power supply connection 230 V, on site 10 A
- Current for external devices: 24 V DC connection; max. 1000 mA
- Accumulator specifications: 24 V; 700 mAh
-
Temperature range: –15 °C to +50 °C; only for dry rooms
Slimdrive SL-T30: +10 ºC to +50 °C
Slimdrive SL-RD: +10 ºC to +50 °C - IP rating: IP 20
Subject to change