Chapter 1: General Information

1.1 Installation Instructions

This manual provides installation instructions for the following ED50/ED100/ED250 (fine cover) door configurations. Reference Para. 2.2 and Para. 2.3 for illustrations.

Single Doors

  • RH and LH pull
  • RH and LH push
  • RH and LH pull as push

Double Doors

  • Pull
  • Push
  • Pull as push
  • Double egress

Companion Doors

  • Push
  • Pull
Notice

For ED50/ED100/ED250 Fine Cover and Header Setup and Troubleshooting, reference the ED50/ED100/ED250 Setup and Troubleshooting Manual DL4617-002.

dormakaba.us Website

Manuals are available for review, download, and printing on the dormakaba.us website.

1.1.3 Dimensions

Unless otherwise specified, all dimensions are given in both inches (") and [mm].

1.1.4 Building Codes and Standards

ED50/ED100/ED250 installation: observe applicable national and local building codes.

1.1.5 Symbols used in these instructions

Warning

This symbol warns of hazards which could result in personal injury or threat to health.

Caution

This symbol warns of a potentially unsafe procedure or situation.

Notice

Draws attention to important information presented in this document.

Tips and Recommendations

Clarifies instructions or other information presented in this document.

Chapter 2: Product Overview

2.1 Types of Door Panels

Table 2.1.1 ED50 Low Energy Door Panel

Exterior and interior applications. Prevailing conditions at opening must be considered.
Parameter Imperial Metric
Maximum door width 48" [1219 mm]
Maximum door weight 220 lbs [100 kg]

Table 2.1.2 ED100 Low Energy Door Panel

Application Max Width Max Weight
Exterior 48" [1219 mm] 220 lbs [100 kg]
Interior 48" [1219 mm] 600 lbs [272 kg]

Table 2.1.3 ED100 Full Energy Door Panel

Exterior and interior applications
Maximum door width 48" [1219 mm]
Maximum door weight 220 lbs [100 kg]

Table 2.1.4 ED250 Low Energy Door Panel

Application Max Width Max Weight
Exterior 48" [1219 mm] 600 lbs [272 kg]
Interior 48" [1219 mm] 800 lbs [317 kg]

Table 2.1.5 ED250 Full Energy Door Panel

Exterior and interior applications
Maximum door width 48" [1219 mm]
Maximum door weight 320 lbs [272 kg]
Exterior Door Use Notice

To insure proper suitability for exterior door use, the following topics must be addressed in the context of the door application setting:

  • For site-specific use factors such as high wind conditions and/or building pressure consult the factory.
  • Door width, height, weight, and usage patterns.
  • Observable prevailing conditions at the opening under which the operator is expected to perform. In some instances, this may require increased force settings to counteract these conditions.
  • Door mounted presence sensors: When attempting to overcome these forces, it is strongly suggested that door mounted presence sensors be employed to enhance pedestrian safety through the opening.
Installation on an Interior Building Surface

The ED50/ED100/ED250 with fine cover must be installed on an interior building surface.

2.2 Single & 2.3 Double Door Configuration Examples

Refer to installation diagrams for the following configurations:

  • LH push / RH push
  • LH deep pull / RH deep pull
  • LH pull as a push / RH pull as a push
  • Double egress
  • Companion door (push/pull without cover)

2.4 - 2.6 Operator, Terminals & Guide Pins

Sections 2.4 through 2.6 detail the specific operator units (ED50 vs ED100/ED250) and accessory terminals.

Fig 2.6.2 ED100/ED250 Backplate Screw Kit (DK4053-010)
  • #12 x 2 1/2" Phillips FHWS (DF0670 000)
  • 1/4-20 x 1 1/2" PFHMS (DF0671-000)

Safety Information & Labels

Essential safety checks for Automatic Swinging Doors and Low Energy Swinging Doors.

Annual Compliance Inspection

Inspect for and complies with ANSI A156.19 (Low Energy) or A156.10 (Full Energy). Have door inspected by an AAADM certified inspector at least annually.

Daily Safety Checks

  1. Activate the door. Door should open at a slow smooth pace (4 or more seconds) and stop without impact.
  2. Check Open Time. Door must remain fully open for a minimum of 5 seconds before beginning to close.
  3. Check Closing. Door should close at a slow, smooth pace (4 or more seconds) and stop without impact.
  4. Inspect Floor. It should be clean with no loose parts that might cause user to trip or fall. Keep traffic path clear.
  5. Inspect Condition. Evidence of damage or missing signage. Hardware should be in good condition.

DO NOT USE DOOR if it fails any of these safety checks or if it malfunctions in any way. Call a qualified automatic door service company.

Required Decals

  • "Automatic Caution Door" (DD0586-010)
  • "Activate Switch to Operate" (DD0758-010)
  • "Push to Operate" (DD0762-010)
  • "Pull to Operate" (DD0762-020)
  • "Do Not Enter" (DD0739-020)
  • AAADM Safety Label

2.8 Fine Cover Kits

Table 2.8.1 Fine Cover Kit Part Numbers
Part Number Description
DK3401-01X Fine cover kit basic
DK3401-05X Fine cover professional single
DK3401-07X Fine cover professional pair

Kit includes items such as fine covers, end cap sets, spindle covers, backplates, logo plates, and templates.

Hardware and Accessories

2.10 Axle Extensions

  • 20 mm axle extension (DC4679-001) - 3/4"
  • 30 mm axle extension (DC4679-002) - 1 1/8"
  • 60 mm axle extension (DC4679-003) - 2 3/8"
  • 90 mm axle extension (DC4679-004) - 3 9/16"

Push & Pull Arm Kits

  • Standard push arm (DC4677-01X)
  • Deep push arm (DC4677-02X)
  • Pull arm (DC4678-01X)
  • Deep pull arm (DC4678-02X)

2.16 Connection Cables

Includes Sync cables and Power connect cables of various lengths (e.g., DX3485-030 for 2030mm sync).