17.1 Push Arm Backplate Mounting

Mount backplate, push arm application for Companion door installation.

[Refer to Fig. 17.1.1 and Fig. 17.1.2 in original manual]

Key Mounting Dimensions
Measurement Description Inches Metric [mm]
Axle Centerline to Edge 8 9/16” [216.7]
Vertical Spacing A 1” [25.4]
Vertical Spacing B 1 7/8” [48]
Vertical Spacing C 1 1/16” [26.9]
Spacer 9/16” [13.5]
Axle Centerline (Secondary) 5 3/4” [146.3]
Fig. 17.1.1 & 17.1.2: ED100/ED250 Companion backplate template; LH push version.
NOTICE: Template documents a Left Hand (LH) push installation. Template must be mirrored for a Right Hand (RH) push installation.

Installation Steps

  • Using backplate template (Fig. 17.1.1 and 17.1.2), locate left hand and right hand backplate mounting holes on door frame/wall.
  • Place backplate on door frame/wall and align with the mounting hole locations.
  • Check hinge pin centerline to edge of backplate distance.
  • Check backplate for level; adjust if necessary.
  • Mark backplate mounting hole locations.
  • Remove backplate and drill holes based on fastener selected for door frame/wall material.
  • Reference Para. 2.1 for backplate mounting screw kit.
  • Use appropriate wall anchors if required.
  • Place backplate on door frame/wall and secure with fasteners.

17.2 Install 8816 Closer on Backplate

Push arm mounting application.

Required Parts

Item Description Part Number
1 Backplate, ED operator companion DC3468-050
2 Companion closer adapter DC3468-070
3 #4 x 1/4-20 x 5/8" Philips flat head screw DF0399-00G
4 1/4-20 x 1" Philips FHMS undercut DF3101-01Z
5 Door closer, 8816 08210970
NOTICE: Verify closer spring size prior to installation.
NOTICE: For push arm application, use PUSH (J) mounting holes (see Fig. 17.2.3).
Fig. 17.2.3 & 17.2.4: Closer adapter and closer assembly mounting to backplate.

17.3 Push Arm Installation

17.3.1 Push Arm Hardware

Reference Para. 9.2 for push arm hardware details.

17.3.2 Attach Drive Arm to Closer

  • Insert axle extension (Fig. 17.3.2) into drive arm.
  • Move arm to 8816, inserting arm into 8816 pinion at a 90° angle.
  • Insert M8 SHCS through drive arm and axle extension. Thread SHCS into 8816 pinion and tighten.
NOTICE: Use torque wrench (25 ft-lbs) to tighten SHCS to 17 ft-lb [23 Nm].

17.3.3 to 17.3.6: Adjustment Arm and Shoe Installation

Fig. 17.3.4: Push arm screw kit (DK2719-010)
  • 1: 10-24 x 1 1/2" pan head Philips slotted barrel nut (DF2718-01Z)
  • 2: 10-24 x 1/2" pan head Philips screw (DF3278-01Z)
  1. Drill holes: Drill two holes in door for adjustment arm shoe fasteners. Reference push arm installation template (Chapter 16) for location.
  2. Install adjustment arm: Fasten adjustment arm assembly to door. Ensure arm is at installation height as shown on template.
    Check: Check shoe for level as fasteners are tightened.
  3. Connect adjustment arm to drive arm:
    • Loosen the two adjustment M6 x 10 mm flanged button head screws.
    • Using square, position adjustment arm assembly at 90° angle to door.
    • Adjust length of adjustment arm until drive arm ball head is aligned with adjustment arm socket.
    • Insert adjustment arm ball head into drive arm socket.
    • Secure adjustment arm position by tightening the two M6 x 10 mm flanged button head screws.
  4. Install covers: Install shoe screw covers.

17.3.7 Door Closer Adjustments

Please reference Chapter 19 for door closer adjustments.