Product Overview
The ED100 is dormakaba’s most versatile operator—functioning as either a low energy operator or a power operated pedestrian unit, the ED100 operator is ideal for ADA-compliant entrance applications.
The ED100 is field adjustable to work as a "knowing act" low energy operator, or a power operated pedestrian "full energy" unit with required additional equipment. With a multitude of adjustable features, you have the flexibility to fine tune the operator to meet opening requirements.
The ED100 is a highly adjustable, smartly engineered operator system at home in a variety of door systems, meeting the stringent requirements of ANSI 156.10, ANSI 156.19, UL325 and UL 10B.
Standards of Compliance & Configuration
The ED100 operator is set to low energy (A156.19) conformance from the factory. Upon installation, the ED100 can be configured to meet:
- ANSI/BHMA A156.19: U.S. Standard for Power Assist and Low Energy Power Operated Doors.
- ANSI/BHMA A156.10: U.S. Standard for Power Operated Pedestrian Doors (Full Power or Full Energy). *Additional equipment required.
Low Energy Power Operated Door (ANSI A156.19)
A door with a power mechanism that opens the door upon receipt of a knowing act activating signal, does not generate more kinetic energy than specified in ANSI A156.19, and includes provisions to reduce the chance of user injury or entrapment. Design factors include:
- Reduced dynamic door panel contact forces
- Reduced static door panel contact forces
- Time delays
- Low opening and closing speeds
- Force limitations
- Signage
Power Operated Pedestrian Door (ANSI A156.10)
A Full Power or Full Energy door with a power mechanism that opens the door upon receipt of a signal from an activating device or sensor. It includes provisions to reduce the chance of user injury or entrapment using specific variants based on door opening and traffic patterns:
- Guide rails
- Activation sensors
- Presence sensors
- Control Mats
- Safety Zones
- Time Delays
- Closing speed
- Closing Force
Technical Specifications
Configuration & Dimensions
| Operator Types | Surface applied, Overhead concealed Single, Paired and Dual Egress Openings |
|---|---|
| Header Dimensions (H × D) |
Narrow Header: 4" x 6" (Length as required) Fine Cover: 2-3/4" x 5-1/8" (Length as required) |
| Operator Weight | 26.5 lb |
| Internal Power Supply | 24 volts DC ± 5% 1.5 Amps (available for accessories) |
| Maximum Door Opening Angle | 110° (door stop recommended) |
| Wire Size (Max) | 16 AWG for incoming power 18 AWG for all other connections |
| Maximum Door Weight |
600 lb at maximum door width of 48" (Low Energy [ANSI A156.19]) *For Full Energy [ANSI A156.10] applications with door weights above 200 lb, contact Technical Support. |
| Door Width Constraints |
Minimum: 28" for surface applied, 36" for overhead Maximum: 48" |
Installation Hardware Specs
| Axle Extensions | 13/16" (20 mm), 1-3/16” (30 mm), 2-3/8" (60 mm) |
|---|---|
| Reveal Depth (Pull arm with track) | 1-3/16” (30 mm) |
| Max Reveal Depth (Pull arm with CPD lever & track) | 2-1/4" |
| Reveal Depth (Standard push arm) | 0 to 9-3/4" |
| Reveal Depth (Deep push arm) | 8” minimum to 19-3/4" |
Electrical Specifications
| Ambient Temperature | 5°F – 122°F |
|---|---|
| Power Supply | 115 volts AC ± 10%, 50/60 Hz Maximum 6.6 Amps, (SELV) |
| Branch Circuit Protection | Maximum 15 Amps, dedicated branch circuit (provided by others) |
| Protection Class | NEMA 1 |
| Power Wiring | 12 AWG (black, white, bare copper ground) |
| Operating Noise | Maximum 50 db(A) |
Inputs & Outputs
| Activation Inputs (X4) | Interior, exterior (Normally open contact) |
|---|---|
| Safety Sensors (X5) | Swing, approach sides (Normally closed contact) |
| Night/Bank (Intercom, X10) | 8 to 24 volts DC/volts AC + 5% |
| Night/Bank (Key switch, X1) | Configure for Normally Open or Normally Closed (d2 parameter) |
| Deactivation of Drive Function (X6) | Configure for Normally Open or Normally Closed (d1 parameter) |
| Door Status Output (X7) | Door closed, Door open, Door closed/locked (Sr parameter: Common, Normally Open, Normally Closed) |
Operating Specifications
| Parameter | Full Energy (F.E.) 1 | Low Energy (L.E.) 1 |
|---|---|---|
| Automatic Closing Torque 3 | Min: 14.8 lb-ft | Max: 110.6 lb-ft (F.E.), 49 lb-ft (L.E.) | |
| Manual Closing Torque 3 | Min: 9.6 lb-ft | Max: 27.3 lb-ft | |
| Max Opening Speed 2 | 50 °/s | 27 °/s |
| Max Closing Speed 2 | 50 °/s | 27 °/s |
Notes:
- F.E.: ED100 configured for full energy. L.E.: ED100 configured for low energy.
- Speeds automatically limited depending on door weight, set during learn cycle.
- In push version of slide channel with track installation type, forces are reduced by approximately 33%.
Integrated Functions
| Hold Open Time | Automatic opening (dd): 0 to 30s Night/bank (dn): 0 to 30s Manual opening (do): 0 to 30s |
|---|---|
| Door Blocking Behavior (hd) | Automatic, manual door modes |
| Electric Strike Delayed Opening (Ud) | 0 to 4 seconds |
| Locking Device Feedback (X3) | Motor lock |
| Wind Load Control (Fo, Fc) | Max 33.7 lb-ft (150 N) |
| Voltage Independent Braking Circuit | Adjustable with potentiometer |
| Cycle Counter (CC) | 0 to 1,000,000 |
| Power Assist Function (hA, hF, hS) | Drive support for manual opening door |
| Push & Go Function (PG) | Auto opening of door at 4° open |