News

Dorma ED100: Low Energy & Power Door Operator Factsheet

Product Overview

The ED100 is dormakaba’s most versatile operator—functioning as either a low energy operator or a power operated pedestrian unit, the ED100 operator is ideal for ADA-compliant entrance applications.

The ED100 is field adjustable to work as a "knowing act" low energy operator, or a power operated pedestrian "full energy" unit with required additional equipment. With a multitude of adjustable features, you have the flexibility to fine tune the operator to meet opening requirements.

The ED100 is a highly adjustable, smartly engineered operator system at home in a variety of door systems, meeting the stringent requirements of ANSI 156.10, ANSI 156.19, UL325 and UL 10B.

Standards of Compliance & Configuration

The ED100 operator is set to low energy (A156.19) conformance from the factory. Upon installation, the ED100 can be configured to meet:

  • ANSI/BHMA A156.19: U.S. Standard for Power Assist and Low Energy Power Operated Doors.
  • ANSI/BHMA A156.10: U.S. Standard for Power Operated Pedestrian Doors (Full Power or Full Energy). *Additional equipment required.

Low Energy Power Operated Door (ANSI A156.19)

A door with a power mechanism that opens the door upon receipt of a knowing act activating signal, does not generate more kinetic energy than specified in ANSI A156.19, and includes provisions to reduce the chance of user injury or entrapment. Design factors include:

  • Reduced dynamic door panel contact forces
  • Reduced static door panel contact forces
  • Time delays
  • Low opening and closing speeds
  • Force limitations
  • Signage

Power Operated Pedestrian Door (ANSI A156.10)

A Full Power or Full Energy door with a power mechanism that opens the door upon receipt of a signal from an activating device or sensor. It includes provisions to reduce the chance of user injury or entrapment using specific variants based on door opening and traffic patterns:

  • Guide rails
  • Activation sensors
  • Presence sensors
  • Control Mats
  • Safety Zones
  • Time Delays
  • Closing speed
  • Closing Force

Technical Specifications

Configuration & Dimensions

Operator Types Surface applied, Overhead concealed
Single, Paired and Dual Egress Openings
Header Dimensions (H × D) Narrow Header: 4" x 6" (Length as required)
Fine Cover: 2-3/4" x 5-1/8" (Length as required)
Operator Weight 26.5 lb
Internal Power Supply 24 volts DC ± 5% 1.5 Amps (available for accessories)
Maximum Door Opening Angle 110° (door stop recommended)
Wire Size (Max) 16 AWG for incoming power
18 AWG for all other connections
Maximum Door Weight 600 lb at maximum door width of 48" (Low Energy [ANSI A156.19])
*For Full Energy [ANSI A156.10] applications with door weights above 200 lb, contact Technical Support.
Door Width Constraints Minimum: 28" for surface applied, 36" for overhead
Maximum: 48"

Installation Hardware Specs

Axle Extensions 13/16" (20 mm), 1-3/16” (30 mm), 2-3/8" (60 mm)
Reveal Depth (Pull arm with track) 1-3/16” (30 mm)
Max Reveal Depth (Pull arm with CPD lever & track) 2-1/4"
Reveal Depth (Standard push arm) 0 to 9-3/4"
Reveal Depth (Deep push arm) 8” minimum to 19-3/4"

Electrical Specifications

Ambient Temperature 5°F – 122°F
Power Supply 115 volts AC ± 10%, 50/60 Hz Maximum 6.6 Amps, (SELV)
Branch Circuit Protection Maximum 15 Amps, dedicated branch circuit (provided by others)
Protection Class NEMA 1
Power Wiring 12 AWG (black, white, bare copper ground)
Operating Noise Maximum 50 db(A)

Inputs & Outputs

Activation Inputs (X4) Interior, exterior (Normally open contact)
Safety Sensors (X5) Swing, approach sides (Normally closed contact)
Night/Bank (Intercom, X10) 8 to 24 volts DC/volts AC + 5%
Night/Bank (Key switch, X1) Configure for Normally Open or Normally Closed (d2 parameter)
Deactivation of Drive Function (X6) Configure for Normally Open or Normally Closed (d1 parameter)
Door Status Output (X7) Door closed, Door open, Door closed/locked
(Sr parameter: Common, Normally Open, Normally Closed)

Operating Specifications

Parameter Full Energy (F.E.) 1 Low Energy (L.E.) 1
Automatic Closing Torque 3 Min: 14.8 lb-ft | Max: 110.6 lb-ft (F.E.), 49 lb-ft (L.E.)
Manual Closing Torque 3 Min: 9.6 lb-ft | Max: 27.3 lb-ft
Max Opening Speed 2 50 °/s 27 °/s
Max Closing Speed 2 50 °/s 27 °/s

Notes:

  1. F.E.: ED100 configured for full energy. L.E.: ED100 configured for low energy.
  2. Speeds automatically limited depending on door weight, set during learn cycle.
  3. In push version of slide channel with track installation type, forces are reduced by approximately 33%.

Integrated Functions

Hold Open Time Automatic opening (dd): 0 to 30s
Night/bank (dn): 0 to 30s
Manual opening (do): 0 to 30s
Door Blocking Behavior (hd) Automatic, manual door modes
Electric Strike Delayed Opening (Ud) 0 to 4 seconds
Locking Device Feedback (X3) Motor lock
Wind Load Control (Fo, Fc) Max 33.7 lb-ft (150 N)
Voltage Independent Braking Circuit Adjustable with potentiometer
Cycle Counter (CC) 0 to 1,000,000
Power Assist Function (hA, hF, hS) Drive support for manual opening door
Push & Go Function (PG) Auto opening of door at 4° open