News

Comprehensive Guide: Dorma ED 100 & 250 Operator Specs

Next section

Next page: →

Product Overview

With their ED 100 and ED 250, dormakaba offers electromechanical swing door operators designed for versatility. The system allows you to select the version that best matches your prevailing door-leaf width and weight.

  • ED 100: Suitable for doors up to 1100 mm wide or 160 kg in weight.
  • ED 250: Designed for doors up to 1600 mm wide or 400 kg in weight.

The operators feature a modular design and force balancing technology, ensuring better distribution of internal forces and self-aligning gear components.

Benefits

  • Flexible configuration: Customers only pay for the functions they actually require.
  • Low-noise application: Achieved through a multi-stage gear system.
  • Elegant visual appearance: dormakaba design provides an operator height of only 70 mm.
  • Durability: Better gear durability due to force balancing technology.
  • Integrated smoke detector: Available as a standard option.
  • New EVAC function: The operator does not switch off completely in an alarm event; it can be passed barrier-free via Power-Assist or Night/Bank modes.
  • New SPV function: Additional parameter level to optimally adapt drive parameters to pressure conditions during an alarm.

Fields of Application

  • Single- or double-leaf swing doors.
  • Interior and exterior doors.
  • Fire and smoke doors (both slide channel and standard arm versions).
  • Rarely and heavily frequented doors (thanks to low- and full-energy versions).
  • Full-automatic swing doors with radar motion control (high torque).
  • Heavy doors & staircases: Especially with smoke extraction and pressure ventilation systems (EVAC / SPV function).

Selection Guide

Choose between the ED 100 and the ED 250 based on your door dimensions. Note: Additional door components such as hinges, seals, or locks may restrict the functional area.

The diagram (not shown) allows determination of max values. All values apply to an ideal door. Achievable speed should be lowered for heavy doors to ensure safety.

Limitation: Specifications valid up to a lintel depth of 300 mm. At depth > 301 mm, ED 250 door panel weight is reduced to 160 kg irrespective of width.

Technical Specifications

General Specifications

Dimensions (W x H x D) 685 x 70 x 130 mm
Dimensions with integrated smoke detector 735 x 70 x 130 mm
Ambient temperature –15 to +50 °C (Only suitable for dry environments)
Relative humidity Max. 93 % (non-condensing)
Power supply 230 V AC 50 Hz +/– 10 %
Power supply for external accessories 24 V DC +/– 10 %, 1.5 A
Class of protection IP 20
Opening angle Max. 110°
Min. clearance between hinges (double systems) 1,400 mm (1,450 mm for ESR)
Weight of single version 12 kg
Manufactured to ISO 9001 Yes
Environmental Product Declaration (ISO 14025) Yes (EPD-DOR-2012211-E)

Performance Data Comparison

Feature ED 100 ED 250
Max. Power Consumption 120 Watts 240 Watts
Closing Force (EN 1154) EN 2 – 4 (adjustable) EN 4 – 7 (adjustable)**
Max. Door-Leaf Weight (Reveal ≤ 300mm) 160 kg 400 kg
Max. Door-Leaf Weight (Reveal 301-500mm) N/A 160 kg
Door-Leaf Width 700 – 1,100 mm 700 – 1,600 mm
Opening Speed (0 – 90°) 4* – 12 seconds 3* – 12 seconds
Closing Speed (90 – 0°) 5* – 21 seconds 4* – 21 seconds
Axle Extension 20/30/60 mm 20/30/60/90 mm
Reveal Depth (Slide Channel) +/- 30 mm +/- 30 mm
Reveal Depth (Slide Channel CPD) 30 – 60 mm 30 – 60 mm
Reveal Depth (Standard Arm) 0 – 300 mm 0 – 500 mm (0-350 mm for fire protection)

* Max speeds are achieved only in full-energy mode, with low door panel weight and taught opening angle of at least 95°. Automatically limited in low-energy mode (EN 16005, DIN 18650, etc.).

** EN 7: lintel depth max. 125 mm.

Integrated Functions & Inputs/Outputs

Category Details
Hold-open time 30 s (180 s optional)
Blocking behavior Reversing / Door closer function
Wind load control Up to 150 N (Voltage-independent braking circuit, adjustable)
Electronic latching action pulse Force adjustable
Integrated program switch OFF, AUTOMATIC, PERMANENT OPEN, EXIT ONLY (single-leaf only)
User Interface Information display, Status indicator, Parameterisation
Upgrade Slot For dormakaba Upgrade Cards (Functional range extension)
Update Interface Firmware update
TMP Temperature Management Program (Overload protection)
IDC Initial Drive Control (Driving phase optimisation)
Power Assist Servo-supported manual opening
Push & Go Door opens when moved manually by 4°
Inputs (Terminals max 1.5 mm²)
  • Potential-free activator (Inside/Outside NO contact)
  • Energized activator (8–24 V DC/AC + 10%)
  • Night-/Bank (NO/NC contact)
  • Safety sensor (Hinge side/Opposite hinge side NC contact)
  • Test signal (for safety sensors)
  • Emergency-Off/Lock switch (NC/NO contact)
Outputs (Terminals max 1.5 mm²)
  • Potential-free door status contact (Door closed, Door open, Malfunction)
Previous
Dorma ED 100/250 Extended Cover Installation Guide | Pro
Next
Dorma ED 100 & ED 250: Technical Mounting Dimensions

Leave a Comment