5. Technical Specification

Product Specifications
Manufacturer ASSA ABLOY Entrance Systems AB
Address Lodjursgatan 10, SE-26144 Landskrona, Sweden
Type ASSA ABLOY SL300
Mains Power Supply 100 V AC -10% to 240 V AC +10%, 50/60Hz, fuse 10 AT (building installation)
Power Consumption Max. 200 W
Degree of Protection IP20
Auxiliary Voltage 24 V DC, 640 mA
Recommended Max. Door Weight Bi-parting (SL300-2): 100 kg/leaf
Single Slide (SL300-R/L): 120 kg
Clear Opening Bi-parting (SL300-2): 1100 - 2000 mm
Single Slide (SL300-R/L): 850 - 2000 mm
Opening and Closing Speed Variable up to approx. 1.2 m/s (SL300-2)
Hold Open Time 0 - 60 s
Ambient Temperature -20 °C to +50 °C
Relative Humidity Max. 85% (non-condensing)
Approvals Third party approvals from established certification organizations valid for safety in use. For indoor use only.
Note! The mains power supply shall be installed with protection and an all-pole mains switch with isolating capability of Category III, at least 3 mm between contacts, shall be installed according to local regulations. These articles are not provided with the door.

6. Design and Function Description

6.1 Design

The sliding door operator ASSA ABLOY SL300 works electromechanically. The system components including the motor, control unit, transmission, optional battery, and electromechanical locking device are all assembled in a support beam.

The motor and gear box transmit movement to the door leaves by means of a tooth belt. The door leaf is fitted to a door adapter/carriage wheel fitting and hangs on a sliding track. Movement of the bottom of the door leaf is controlled by the floor guides.

6.2 Function

Opening

When an OPENING IMPULSE is received by the control unit, the motor starts and transmits movement to the door leaves, which move to the open position.

Closing

The closing starts when no OPENING IMPULSE is received and the HOLD OPEN TIME has run out.

6.3 Safety Functions Integrated in the Operator

To permit safe passage between closing doors, the doors immediately reverse if an obstruction is detected, then resume their interrupted movement at low speed to check whether the obstruction has disappeared or not.

If an obstruction is detected while the door is opening, the doors immediately stop and then close after a time delay.

6.4 Microprocessor for Precise Control

The microprocessor has a routine for self-monitoring, which detects any interference or faulty signals in door operation. If an input signal does not correspond to the preprogramming, the microprocessor automatically takes necessary actions to ensure safe door operation.

6.5 Power Failure

The ASSA ABLOY SL300 can be equipped with a battery unit that automatically opens the doors in the event of a power failure. The operator is not allowed to be used in an escape route.