6. Configurations
6.1 Parameter Overview
Configurations of the DFA 127 can only be made with the electronic BDE-D. If a toggle switch is connected, a BDE-D must be connected briefly for the configuration.
Further information for parameter changes can be taken from the user manual of the BDE-D (no. 903 109 271).
Important Note: Please always leave the configuration review sheet in the drive!
6.2 Parameter Description
| Parameter | Setting Range | Factory Default | Description |
|---|---|---|---|
| Driving Cycle | |||
| Closing speed | 0 - 40 (5 – 20 s) |
18 | Slider control with 40 steps |
| Opening speed | 0 - 40 (3 - 20 s) |
36 | Slider control with 40 steps |
| Time Delay Open | |||
| Time delay open | 0 - 40 (0 - 60 s) |
2 |
Effective with AKA, AKI and push to actuate 0 - 20: Steps of 1 s 21 - 40: Steps of 2 s |
| Time delay SSK | 0 – 40 (0 - 60 s) |
4 |
Effective with SSK 0 - 20: Steps of 1 s 21 - 40: Steps of 2 s |
| Drive | |||
| Opening angle | 0 - 40 | 35 | The opening angle is estimated during the calibration run and is equivalent to the value of 40. |
6.3 Different Factory Defaults for Door Types Low Energy
| Parameter Category | Parameter | Factory Default |
|---|---|---|
| Driving Cycle | Closing speed | 10 |
| Opening speed | 20 |