Record DFA 127 Full Power Configurations & Parameters

DFA 127 Full Power: Configurations & Parameter Settings | Operating Instructions

6. Configurations

6.1 Parameter Overview

Configurations of the DFA 127 can only be made with the electronic BDE-D. If a toggle switch is connected, a BDE-D must be connected briefly for the configuration.

Further information for parameter changes can be taken from the user manual of the BDE-D (no. 903 109 271).

6.2 Parameter Description

Factory Defaults and Settings for DFA 127 Full Power
Parameter Setting Range Factory Default Description
Driving Cycle
Closing speed 0 - 40
(5 – 20 s)
18 Slider control with 40 steps
Opening speed 0 - 40
(3 - 20 s)
36 Slider control with 40 steps
Time Delay Open
Time delay open 0 - 40
(0 - 60 s)
2 Effective with AKA, AKI and push to actuate
0 - 20: Steps of 1 s
21 - 40: Steps of 2 s
Time delay SSK 0 – 40
(0 - 60 s)
4 Effective with SSK
0 - 20: Steps of 1 s
21 - 40: Steps of 2 s
Drive
Opening angle 0 - 40 35 The opening angle is estimated during the calibration run and is equivalent to the value of 40.

6.3 Different Factory Defaults for Door Types Low Energy

Low Energy Configuration Defaults
Parameter Category Parameter Factory Default
Driving Cycle Closing speed 10
Opening speed 20
Previous