Dormakaba ED100/ED250 OHC Owner's Manual - Chapter 5
Daily Safety Check Procedure
All figures and diagrams are for purposes of illustration only and are from AAADM automatic swinging door manual, reprinted with permission.
5.1 Power Operated Swing Doors
5.1.1 Performing Daily Safety Checks
Perform safety checks daily on your automatic swinging door to insure your customer and employee safety. The daily safety checks are listed in Chapter 4, AAADM safety information labels.
Perform these checks while traffic is restricted from all detection and sensing zones.
5.1.2 Sensor Activation, Safety Sensor Detection
Check activation sensor by walking toward door opening at moderate speed, door should:
- Start opening when you are about four feet from door.
- Open smoothly.
- Stop at fully open without impact.
Move slowly through door opening (approximately six inches/second) stop in door swing path, and pause for ten seconds.
- Door should remain open.
Sensor Zone Exit Check:
- If two way traffic, repeat from other side of door.
- Step out of sensor zone activating area.
- After a brief delay (minimum 1.5 seconds) door should close smoothly and without impact.
One Way Traffic Check:
For one way traffic, approach safety side of door and have someone else approach activating side.
- Door equipped with overhead mounted safety sensor: (See Fig 5.1.1) As long as you are in safety area of door it should not open.
- Door equipped with door mounted safety sensors: (See Fig 5.1.2, Fig. 5.1.3) Door may start to open but should reverse, stop or slow down.
Motionless Check:
Stand motionless in door for at least 4 seconds.
- Door equipped with overhead mounted presence sensor: (See Fig 5.1.1) Door should not close.
- Door equipped with door mounted safety sensors: (See Fig 5.1.2, Fig. 5.1.3) Door may start to close but should reverse, stop or slow down.
5.1.3 Swing Door Double Egress; Knowing Act Switch Activation
- Double egress doors are commonly activated by knowing act switch(es).
- Operate knowing act device, doors should:
- Open smoothly and stop at fully open without impact.
- Remain open for a minimum of five seconds before closing.
- As door closes, approach door from approach side:
- Door should reopen.
- Continue across threshold and stand motionless for 10 seconds:
- Door should not contact you.
- Continue through door, the door should:
- Start closing after a minimum of five seconds.
- Close smoothly and without impact.
- Approach safety zone side of door:
- If door equipped with overhead safety sensor (See Fig. 5.1.4) door should not open as long as you are in safety zone when door closed.
- If door equipped with door mounted safety sensor (See Fig. 5.1.5) door may start to open but should reverse, stop or slow down.
5.2 Low Energy Power Operated Swing Doors
5.2.1 Performing Daily Safety Checks
Perform safety checks daily on your low energy swing door to insure your customer and employee safety. These daily safety checks are also listed in Chapter 4, Safety Information labels, low energy swinging doors.
- Activate the door by a knowing act (Para.3.3).
- Door should open at a slow smooth pace (4 seconds or more) and stop without impact.
- Door must remain fully open for a minimum of 5 seconds before beginning to close.
- Door should close at a slow smooth pace (4 seconds or more) and stop without impact.
- Inspect the floor area, it should be kept clean with no loose parts that might cause user to trip or fall. Keep traffic path clear.
- Inspect door's overall condition. The appropriate signage (Chapter 7) should be present and all hardware should be in good condition.
- Have door inspected by a dormakaba USA Inc. AAADM certified technician at least annually.
If there are any problems, discontinue door operation immediately and secure the door in a safe manner.
Call your local dormakaba USA Inc. distributor for repair.