3. Product Description

3.1 Overview

Figure 1: Component Overview

The following list details the main components of the operator system:

  • 1 Carriers
  • 2 Engaging unit
  • 3 Operator profile
  • 4 Battery
  • 5 Toothed belt
  • 6 Mounting profile
  • 7 LM girder
  • 8 End stop
  • 9 Locking device
  • 10 DRIVE UNIT
  • 11 End plate
  • 12 Logo clip
  • 13 Cover holders
  • 14 Internal cover
  • 15 Connector (control unit to extension module)
  • 16 Extension module
  • 17 CIN (option)
  • 18 Cable duct
  • 19 Hinge profile
  • 20 Deflection device
  • 21 Rubber strip
  • 22 Track profile
  • 23 Counter roller
  • 24 Anti-static brush
  • 25 Adjustable brackets
  • 26 Carriers with engaging unit for 1-leaf units
  • 27 Bag of screws (17508901150 for 2-leaf, 17509001150 for 1-leaf)

3.2 Operating Elements

The control unit features a user interface equipped with 4 keys and a 2-digit display (Figure 2). The keys enable the following functions:

Right Key

  • Open parameters menu
  • Display parameter value
  • Select parameter to be changed
  • Save changed parameter value
  • Open error menu

Bottom Key

  • Scroll through parameters and error messages
  • Decrease the parameter value
  • Opening impulse
  • Teach-in run (press for 3 secs)
  • Factory reset (Fact-Setup) (press for 8 secs)

Left Key

  • Close change parameters
  • Close parameters menu
  • Close error menu
  • Stop service mode (press for 3 secs)

Top Key

  • Scroll through parameters and error messages
  • Increase the parameter value

Left + Right Key (Simultaneously)

  • Error acknowledgement
  • Reset (press for 3 secs)

3.3 Parts Included

The parts included are stated on the delivery note. Note that fixing materials such as dowels and screws are not included unless specified.

3.4 Technical Data

Connection voltage 230 V 50 Hz +10%/-15%
Fuse (supplied by customer) 10 A
Protection class IP 20
Permissible humidity 93% relative humidity, non-condensing
Operating temperature -20°C to +60°C
Power supply for external devices (mains) 24 V DC / max. 2 A short-circuit-proof
Power supply (battery mode failure) 21–27 V DC / max. 2 A short-circuit-proof
Multiport inputs 24 V ±15%

3.5 Closing Edge Protection

Warning Only safety sensors with type approval according to EN 16005 may be used!

3.6 Secondary Closing Edge Protection