9.1 Control Switches
4-position switch PS-4C (operates the electric lock)
| Position | Function Description |
|---|---|
| OFF | The door is closed. The door cannot be opened with inner and outer activation units. The door is locked if an electromechanical locking device has been fitted. The door can be opened with a key switch (if fitted). |
| EXIT (Passage from inside only) | The door is normally locked if an electromechanical locking device has been fitted. The door can only be opened with the inner activation unit and with a key switch (if fitted). |
| AUTO (Normal position) | The door can be opened with the inner and outer manual and/or automatic activators. The electric strike, if fitted, is open. |
| OPEN | The door is held permanently open by the motor. |
9.2 Sync Cable for Double Doors
Used for synchronizing 2 operators.
Note! The connection/marking of the sync cable determines which of the operators is the MASTER and SLAVE.
- Red: MASTER
- Black: SLAVE
9.3 Coordination Unit (Besam SW300 Only)
To coordinate rebated doors in a double door installation and to make sure the doors are closed in the right order.
| Description | Art. No. |
|---|---|
| Rod kit | 1013050 |
| Coordinator top assembly | 1013027 |
9.4 LED Cable
External status indicator LED.
9.5 Battery Backup Unit
Warning: Disconnect mains power when replacing battery. Risk of battery explosion if wrong type of battery is used.
9.6 Double Door Kit
9.7 Closing Time Board Kit (Besam SW300 Only)
To fulfill the DIN 18263-4 standard it is necessary to mount and connect this board to the lock kick.
9.8 Fire Kit (Besam SW300 Only)
For fire door installations.
9.9 Labels
Label kit including all items below:
- Emergency break-out, DIN right door
- Emergency break-out, DIN left door
- Activation by disabled people
- Operator designed for disabled people
- Supervision of child ("Click!")
- Besam door sticker