Safety Accessories
Even though the Besam SL500, Besam SL500 T, and Besam SL500 SL are installed to comply with all applicable safety regulations, it is possible to enhance safety and comfort with the following add-ons. Please contact your local ASSA ABLOY Entrance Systems company for a detailed description.
- Combined motion and presence sensors
- Separate presence sensors
General Accessories
Your Besam SL500-series operator can be further improved with the following add-ons. Contact your local dealer for details.
Cover
Made in clear anodized aluminium as standard. Paint finished in RAL colours or anodizing optional.
Motion Sensors
Motion and presence sensors available. Please refer to separate manuals or installation drawings.
Operation Mode Selectors
See page 9 and separate installation drawing 1013675.
Electrical Locks
There are 4 different types of locks available for the operator:
- Locked with power (LDP) – fail safe
- Locked without power (LD) – fail secure
- Bistable lock (LDB)
- Espagnolette lock (LDE)
Manual Opening Lock Device (MOLD)
For manual unlocking of the electrical lock (LD), locked without power (fail safe).
Supplementary Lock Release
Includes components such as:
- Bending protection
- Lock release kit
- Compression spring
- Wire lock
See separate installation drawing 1013736.
Micro Switch Kit
For indication of door and lock position. This is an older version of LSK.
Locked Door Indicator
For indication of locked lock and closed door for connection to alarm system.
Electrical Emergency Unit with Batteries
Used if a door is required to be opened or closed by means of a rechargeable battery unit and remain in this position in the event of power failure. Authorities can demand that the emergency units are monitored on a regular time basis.
Testing Procedure: Half an hour before this time has elapsed, the following opening impulse generates an emergency opening test. If there is no opening impulse within the next half hour, the operator control unit generates the opening impulse itself.
If the battery opens the door within the limited time, the test is successful and the door resumes the function set by the operation mode selector.
Electrical Emergency Unit with Batteries and Two Motors
Similar to the standard unit, used if a door is required to be opened by means of a rechargeable battery unit and remain in this position in the event of power failure.
Monitoring and testing procedures follow the same logic as the single-motor emergency unit described above.
Emergency Closing with Repeated Closing
If the door is opened by hand after an electrical emergency closing, it will close again automatically.
Break-out Unit PSB
Enables door/side screens to be broken outwards in case of emergency. (See page 16 for details).
Interlocking
Used between two operators when the first operator must close before the other one can open (typical to reduce energy losses and not for security reasons). Interconnecting cable required.
Convenience Battery UPS
Stand-by supply which gives continued operation during short power failures.
External Error Indication
Obtained if a lamp or a buzzer is connected.
Key Switches
(Flush and/or surface mounted). Used to give opening impulse to the door in any operation mode selector setting. Works with electrical emergency unit also during power failure.
Push Button
Used to give opening impulse to the door. See separate installation drawing 656005.
Synchronization
Used between the operators of two single sliding doors, working together in very large openings. Interconnecting cable required.
Open / Close Function
One button impulse will alternate between Open and Close. The door will stand open until next impulse or can, after an adjustable time delay, automatically start to close even if a new impulse is not received.
Fire Alarm Connection
Used to emergency open or fire close the door with mains power on.
Nurse Function
Used mostly in combination as a Nurse-Bed function. Nurse opens the door to partial open position, and bed (connected to inner or outer impulse) opens to full open position.
- Nurse works in operation mode selections Exit and Auto.
- The Nurse impulse has the same hold open time as partial open.
Remote Exit Mode
Remotely put door into Exit via a remote system, like a timer.
Emergency Open Impulse
Used to give opening (fireman's opening) impulse to the door in any operation mode selector setting. Works with electrical emergency unit also during power failure.