Instruction for Safe Operation
Warning: Failure to observe the information in this manual may result in personal injury or damage to equipment.
- To reduce the risk of injury to persons, use this operator with single or double pedestrian swinging or folding doors only.
- Do not use the equipment if repair or adjustment is necessary.
- Disconnect supply when cleaning or other maintenance is to be carried out.
- The operator can be used by children over 8 years of age if they have been instructed by a person in charge of their safety.
- The operator can be used by children 8 years of age or younger if they are supervised by a person responsible for their safety.
- The operator can be used by persons with impaired physical, sensory or mental capacity if they have been instructed by a person in charge of their safety.
- Cleaning and user maintenance shall not be made by children.
- Do not let anyone climb on or play with the door or the fixed/remote controls.
- Risk of battery explosion if wrong type of battery is used.
- In all instances, where work is being done, the area is to be secured from pedestrian traffic, and the power removed to prevent injury.
- The door has no safety during auto-learn cycle. Remain clear of swing path of door, as door may open and close rapidly.
- In the event that the KILL circuit is activated, all Safety Functions of the door will be overridden causing the door to close even though an object or person may be in the door's path of travel, and therefore may be subject to injury. This mode of operation is most generally used to isolate an area in the event of a fire.
- The door set can be operated automatically by sensors or manually by activators. It can also be used manually as a door closer.
Important Information
3.1 Intended Use
The ASSA ABLOY SW200 is an automatic swing door operator developed to facilitate entrances to buildings and within buildings through swing doors. The operator is only for indoor use.
The ASSA ABLOY SW200 is a universal electro-mechanical operator that combines a Heavy Duty (HD) operator for large heavy doors with Low Energy (LE) applications of swing doors. The operator is factory set to Low Energy (LE).
The operator can be surface or concealed mounted on either side of the door header for pull or push action, and is suitable for single doors, double doors, and double egress doors fitted with swing clear hinges, offset or center pivots.
It ensures all-around safety and can be combined with a full range of sensor products providing swing door safety, but also meets the requirements for a low energy operator without any sensors. The operator is connected to the door leaf with a range of different arm systems.
For use see User manual 1009729.
3.2 Safety Precautions
- Do not climb on door parts.
- Do not let children play with the door or the fixed controls.
- Be sure to complete a risk assessment according to "Guide for installers of Powered Pedestrian Swing Doors" (PRA-0006) and fill in the "Site Acceptance Test" (PRA-0007) before taking the door into operation.
- To avoid bodily injury, material damage and malfunction of the product, the instructions contained in this manual must be strictly observed during installation, adjustment, repairs and service etc.
- Training is needed to carry out these tasks safely. Only ASSA ABLOY Entrance Systems-trained technicians should be allowed to carry out these operations.
3.3 Electronic Equipment Reception Interference
The equipment may generate and use radio frequency energy and if not installed and used properly, it may cause interference to radio, television reception or other radio frequency type systems.
If interference occurs (determined by turning the equipment off and on), the user is encouraged to try to correct it by:
- Re-orienting the receiving antenna.
- Relocating the receiver with respect to the equipment.
- Moving the receiver away from the equipment.
- Plugging the receiver into a different outlet so that equipment and receiver are on different branch circuits.
- Checking that protective earth (PE) is connected.
3.4 Environmental Requirements
ASSA ABLOY Entrance Systems products are equipped with electronics and may also be equipped with batteries containing materials which are hazardous to the environment. Disconnect power before removing electronics and battery and make sure it is disposed of properly according to local regulations (how and where) as was done with the packaging material.
4. Technical Specifications
Ensure that the door operator with technical specification below is suitable for the installation.
| Manufacturer | ASSA ABLOY Entrance Systems AB |
|---|---|
| Address | Lodjursgatan 10, SE-261 44 Landskrona, Sweden |
| Type | ASSA ABLOY SW200 |
| Mains supply | 100-240 VAC +10/-15%, 50/60 Hz, mains fuse max 10A (building installation) Note: The mains supply shall be installed with protection and an all-pole mains switch with isolating capability of Category III, at least 3 mm between contacts. |
| Power consumption | Max. 300 W |
| Auxiliary voltage | 24 V DC, max. 700 mA |
| Mains fuse F1, F2 | 2 x T 6,3 AH 250 V |
| Door weight/width (Push arm) | EN 4-7, max. 160 kg / 1600 mm |
| Door weight/width (Pull arm) | EN 4-5, max. 100 kg / 1250 mm |
| Door width range | 800 - 1600 mm |
| Max. Inertia J | For PUSH = 160 kgm² (80 kgm² for 180° opening) For PULL = 80 kgm² Inertia = Door weight x (Door width)² / 3 |
| Electro-mechanical locking device | Selectable: 12V DC, max. 1200 mA / 24 V DC, max. 600 mA |
| Door opening angle | PUSH: 80° - 110°, with reveal 0 - 305 mm PULL: 80° - 110°, with reveal 0 - 130 mm PAS: only 80° - 95°, with reveal 0 - 130 mm |
| Opening / Closing time | Opening (0° - 80°): Variable 2 - 12 s Closing (90° - 10°): Variable 4 - 12 s |
| HOLD open time | 1.5 - 30 seconds |
| Ambient temperature | -20 °C to +45 °C |
| Relative humidity | Max. 95% |
| Drive unit weight | 9 kg |
| Class of protection | IP20 |
| Degree of protection (control actuators) | IP54 |
Permitted Door Weight and Width