News

ASSA ABLOY SW100 Parts & Accessories Identification Guide

ASSA ABLOY SW100 Parts & Accessories | Manual

7.1 Arm System, PUSH

Art. No. 1007241BK/SI

PUSH: It is used if the operator is wall mounted on the opposite side compared with the opening direction and that the unit must be approved for fire applications.

7.1.1 PUSH-arm Extensions

345 mm extension

Art. No. 173005BK/SI
Extension Reveal Guide
Extension Type Reveal Range (A)
None (standard arm) 0 - 100 mm
345 mm extension 100 - 215 mm
230 mm + Joint part 215 - 305 mm

230 mm extension

Art. No. 173004BK/SI

Joint part

Art. No. 173191

7.2 Arm System, PUSH-335

Art. No. 1007965BK/SI

PUSH-335: It is used if the operator is door leaf mounted and mounted on the hinge side of the door.

7.3 Arm System, PULL

Art. No. 1008401BK/SI

PULL: It is used if the operator is installed on the wall on the same side as the door swing.

7.4 Arm System, PULL-220

Art. No. 1011998BK/SI

PULL-220: It is used if the operator is installed on the wall on the same side as the door swing and when the door is 450-700 mm wide.

7.5 Reveal Spacer: PULL / PULL-220

Art. No. PULL1014317BK/SI
  • 40 mm (1-9/16")
  • 60 mm (2-3/8")

7.6 20 mm Extension

Art. No. 1011205

Extension 20 mm for PULL/PAS and lower mounting of slide track profile.

7.7 Drive Shaft Extension Kits

Size Art. No.
20 mm (3/4") 173109BK / 173109SI
50 mm (2") 173108BK / 173108SI
70 mm (2-3/4") 173107BK / 173107SI

Lower adapter M8: Used for 20 mm lower installation height. Art. No. 1007618

7.8 Control Switches

7.8.1 ON/OFF/HOLD Open Switch (will not operate electric lock)

P/N: 1003582
Function Position/Wire Description
ON White Impulses from activation units connected to XIMP are forwarded into inner impulse.
OFF Brown Impulses from activation units connected to XIMP are not forwarded into inner impulse. These units cannot open the door.
HOLD Green The door is held permanently open.

7.8.2 4-Position Switch PS-4C (operates the electric lock)

Art. No. 655845
Selection Position Function Description
OFF The door is closed. The door cannot be opened with inner and outer activation units. The door is locked if an electromechanical locking device has been fitted. The door can be opened with a key switch (if fitted).
EXIT Passage from inside only. The door is normally locked if an electromechanical locking device has been fitted. The door can only be opened with the inner activation unit and with a key switch (if fitted).
AUTO Normal position. The door can be opened with the inner and outer manual and/or automatic activators. The electric strike, if fitted, is open.
OPEN Hold Open. The door is held permanently open by the motor.

7.9 Sync Cable for Double Doors (Synchronizing of 2 Operators)

Note! Connect a cable between primary CU and secondary CU. The connection/marking of the sync cable determines which of the operators is the primary and secondary.
  • Rebated door: Primary door must open before secondary; secondary must close before primary.

How to Cut the Jumper for Double Doors

Secondary Side Jumper Primary Side Jumper Jamming Rebated Closing Function Opening Function
No cutting No cutting No No Synchronous Synchronous
No cutting Cut black No Yes Asynchronous Synchronous
Cut red No cutting Yes Yes Asynchronous Asynchronous
Cut red Cut black - - Double egress

Settings for Double Doors

Function Secondary Side Primary Side Common/Individual
Program selection X X Common
Opening time, Closing time, Hold open time X X Common
Close/Continue to open when obstructed X X Common
PAG On/Off X X Common
Level of Power assist (X)* X Common
Lock/Unlock signal voltage X X Individual
Locked without/with power X X Individual

* For "Double egress doors", these functions must be set separately for primary and secondary.

7.10 Extension Units

For installation see page 45.

EXU-SA (Kit for Safety Functions)

Art. No. 1003557

EXU-SI (Kit for Security Functions)

Art. No. 1003554

AIU (Audible Warning Signal)

Art. No. 656083

24 V DC

7.11 Battery Backup Unit

Art. No. 1003567
Warning: Disconnect mains when replacing battery. Risk of explosion if wrong type of battery is used.

7.12 Cover Piece Kit

Art. No. 1009935BK/SI

7.13 Labels

  • Label kit (including all below): Art. No. 1005227
  • Emergency break-out, DIN right door: Art. No. 1001785
  • Emergency break-out, DIN left door: Art. No. 1001786
  • Activation by disabled people: Art. No. 1003963
  • Operator designed for disabled people: Art. No. 1003964
  • Supervision of child: Art. No. 1001695
  • ASSA ABLOY door sticker: Art. No. 1700038
Previous
Assa Abloy SW100 Parts & Accessories Identification List
Next
Assa Abloy SW100 Pre-installation & Safety Guide