Introduction
Regular inspections shall be made according to national regulations and product documentation by an ASSA ABLOY Entrance Systems-trained and qualified technician. The number of service occasions should be in accordance with national requirements and product documentation.
As with all other technical products, an automatic door needs maintenance and service. It is essential to know the importance of maintenance to have a reliable and safe product. Service and adjustments will ensure a safe and proper operation of an automatic door unit.
The “Service Log Book” shall be used together with the “Site Acceptance Test and Risk Assessment” document (PRA-0005) provided. Keep both documents available for maintenance and service records.
Preventive Maintenance Schedule
The table below shows the recommended replacement intervals (in months) for parts during preventive maintenance, based on the operating environment and traffic volume.
| Part Name | Part Number |
Abusive Environment |
High Traffic >100 cycles/hour |
Medium Traffic <100 cycles/hour |
Low Traffic <10 cycles/hour |
|---|---|---|---|---|---|
| Battery | 331013725 | 24 | 24 | 24 | 24 |
| Door Carriage | 331012592 | 12 | 12 | 24 | 36 |
| Tooth Belt | 331016652 | 36 | 48 | 48 | 48 |
| Door Stop | 331012594 | 24 | 24 | 24 | 24 |
| Tension Wheel | 330000837 | 36 | 36 | 36 | 36 |
| Detachment Guard | 331012777 | 60 | 60 | 60 | 60 |
| Anti-rise Kit | 331015924 | 60 | 60 | 60 | 60 |