News

Record STA20 Maintenance: Recommended Spare & Wear Parts

Recommended Spare and Wear Parts - Record STA20 Maintenance

Parts Replacement Interval Table

Spare Part / Wear Part Interval
CO48 (Silicon or Rubber)
Mechanical power storage device for escape routes in France
1 year
Pulley CO48 3 years
Battery 3 years
Antistatic brush 3 years
Door leaf guide (plastic) 3 years
Guiding pad 3 years
Safety blocking ball (TOS Break-out system) 5 years
Pulley If wear is detected
Gear belt If wear is detected
Roller, wheel If wear is detected
Counter wheel If wear is detected
Track If wear is detected
Carriage + Track + Rubber damping profile If wear is detected
Belt clamp If wear is detected
Hinge (plastic) for cladding height 200 mm If wear is detected
Locking device (VRR) If wear is detected
Motor If wear is detected
Leaf central seal If wear is detected
Lateral sealing profile If wear is detected
Floor guide rail If wear is detected
Light barrier If wear is detected
Control Breakdown/Failure
BDE Control unit Breakdown/Failure
BBGV Green break glass housing Breakdown/Failure
Others Breakdown/Failure