News

DORMA ED 100 & ED 250 Technical Specifications | Manual

Next section

Next page: →

Product Overview and Variants

The following technical specifications will help you to check additionally if the system fulfils the requirements. You can start mounting if the system complies with the parameters.

Available Models and Article Numbers
Model Power Size Version Fire Protection Article-No.
ED 100 EN 2 - 4 push-version / pull-version Yes 29222301
ED 250 EN 4 - 6 push-version Yes 29202301
ED 250 EN 4 - 6 pull-version No specifications 29202301
ED 250 EN 4 - 6 pull-version Yes 29202302
ED 250 EN 4 - 5 pull-version Yes 29202303

Required Operating Conditions

Ambient temperature -15 to +50° C
Humidity Only suitable for dry environments; relative humidity max. 93% non-condensing
Power supply 230 V AC +/- 10% 50 Hz
Class of protection IP 20

General Specifications

Dimensions (WxHxD) 685 x 70 x 130 mm
Min. distance between hinges (double-leaf systems) 1,400 mm
Min. distance between hinges with ESR (door coordinator) 1,450 mm
Min. distance between hinges with VARIO Cover 1,500 mm
Operator weight 12 kg
Power supply for external accessories 24 V DC +/- 10%, 1.5 A
Opening angle Max. 110°

Inputs and Outputs

Inputs

Connections Max. 1.5 mm²
Potential-free activator Inside and outside (NO contact)
Night-/Bank (intercom system) 8 - 24 V DC / AC + 10%
Night-/Bank (key switch) NO contact / NC contact
Safety sensor Hinge side and opposite hinge side (NC contact)
Test signal for safety sensor Hinge side and opposite hinge side
Deactivation of operator function (lock switch) NC contact / NO contact

Outputs

Connections Max. 1.5 mm²
Potential-free status indicator
  • Door closed
  • Door open
  • Malfunction

Integrated Functions

Function Description/Value
Latching action Force adjustable
Hold-open time 0 - 30 seconds
Night-/Bank hold-open time 0 - 30 seconds
Blocking behaviour during closing cycle Reversing / Door closer function
Delayed opening for locking mechanism (electric strike) 0 - 1 second/s
Locking feedback contact Motor lock
Wind load control Up to 150 N
Voltage-independent braking circuit Adjustable via potentiometer
LED status indicator
  • Green: Power supply available
  • Red: Malfunction
  • Yellow: Service interval indicator
Integrated program switch OFF, AUTOMATIC, PERMANENT OPEN, EXIT ONLY (single-leaf only)
User interface With information display (Status indicator and parameterisation)
Slot for DORMA Upgrade Cards Extension of functional range
Update interface Firmware update
TMP Temperature Management Program (Overload protection)
IDC Initial Drive Control (Driving phase optimisation)
Cycle counter 0 – 1,000,000 (reasonably subdivided)
Power Assist Function Servo-supported manual opening
Push & Go Function The door opens when it is moved manually by 4°

ED 250 Specific Data

Max. power consumption 240 Watts
Closing force EN 1154 EN 4 – 6 continuously adjustable
Max. door-leaf weight 250 kg (lintel depth ≤ 300 mm, width ≤ 1,400 mm)
190 kg (lintel depth ≤ 300 mm, width ≤ 1,600 mm)
160 kg (lintel depth 301-500 mm)
Door-leaf width 700 – 1,600 mm
Door-leaf width for fire protection doors 700 – 1,400 mm
Max. opening speed** 60° (27°*) / second
Max. closing speed** 60° (27°*) / second
Axle extension 30 / 60 / 90 mm
Lintel depth for slide channel +/- 30 mm
Lintel depth for standard arm 0 – 500 mm

ED 100 Specific Data

Max. power consumption 120 Watts
Closing force EN 1154 EN 2 – 4 continuously adjustable
Max. door-leaf weight 100 kg (lintel depth ≤ 300 mm)
Door-leaf width 700 – 1,100 mm
Max. opening speed** 50° (27°*) / second
Max. closing speed** 50° (27°*) / second
Axle extension 30 / 60 mm
Lintel depth for slide channel +/- 30 mm
Lintel depth for standard arm 0 – 300 mm

* The values in brackets indicate the maximum speed in Low-Energy Mode without Full-Energy or Fire Protection Upgrade Cards.

** Depending on the door-leaf weight automatically limited according to DIN 18650, BS 7036-4 and ANSI 156.19.

Torque Overview

ED 100 Torque

Values in Nm Lintel mounting on hinge side with slide channel (Pull-version) Lintel mounting on opposite hinge side with standard arm (Push-version)
Min (EN 2) Max (EN 4) Min (EN 2) Max (EN 4)
Closing torque (manually) 13 34 13 37
Closing torque (Automatic)** FE: 150 / LE: 67 FE: 150 / LE: 67
Opening torque (manually) 30 50 35 55
Opening torque (Automatic)** FE: 150 / LE: 67 FE: 150 / LE: 67
Opening torque of manually-activated Power-Assist Function* 23 23

ED 250 Torque

Values in Nm Lintel mounting on hinge side with slide channel (Pull-version) Lintel mounting on opposite hinge side with standard arm (Push-version)
Min (EN 4) Max (EN 6) Min (EN 4) Max (EN 6)
Closing torque (manually) 26 65 26 70
Closing torque (Automatic)** FE: 150 / LE: 67 FE: 150 / LE: 67
Opening torque (manually) 55 85 60 90
Opening torque (Automatic)** FE: 150 / LE: 67 FE: 150 / LE: 67
Opening torque of manually-activated Power-Assist Function* 23 23

FE: With Full-Energy or Fire Protection Upgrade Card Full-Energy

LE: Low-Energy basic operator without Upgrade Card

* Power-Assist adjusted to maximum, effective from an opening width of approx. 3°.

** The torque is activated by an automatic opening in AUTOMATIC mode.

Power-Assist Function

The Power-Assist Function may be activated while the door is in door closer mode (parameter Hd = 1). As soon as a user opens the door manually by some degrees, the servo-function supports the manual opening cycle. The servo support automatically adapts to the adjusted size of the door closer.

The level of servo support is adjustable in order to meet the requirements of DIN 18040, DIN Spec 1104, CEN/TR 15894, BS 8300/2100 and document "M", even up to class EN 6.

The smallest adjustable opening torque amounts to 23 Nm/5 lbf., unless the hold-open device is triggered or in the event of a power failure. With the aid of the Power-Assist Function, the system meets the requirements of the European standard EN 1154 and provides barrier-free access during standard operation.

Attention: It is not possible to use the system in conjunction with the Push & Go Function or the wind load control as these functions may affect the easy manual opening.
Previous
DORMA ED 100 & ED 250 Mounting Instructions | Safety Manual
Next
Dorma ED 100/250 Mounting Instructions: Setup & Accessories

Leave a Comment