The following technical specifications will help you to check additionally if the system fulfils the requirements. You can start mounting if the system complies with the parameters.
| Model | Power Size | Version | Fire Protection | Article-No. |
|---|---|---|---|---|
| ED 100 | EN 2 - 4 | push-version / pull-version | Yes | 29222301 |
| ED 250 | EN 4 - 6 | push-version | Yes | 29202301 |
| ED 250 | EN 4 - 6 | pull-version | No specifications | 29202301 |
| ED 250 | EN 4 - 6 | pull-version | Yes | 29202302 |
| ED 250 | EN 4 - 5 | pull-version | Yes | 29202303 |
Required Operating Conditions
| Ambient temperature | -15 to +50° C |
|---|---|
| Humidity | Only suitable for dry environments; relative humidity max. 93% non-condensing |
| Power supply | 230 V AC +/- 10% 50 Hz |
| Class of protection | IP 20 |
General Specifications
| Dimensions (WxHxD) | 685 x 70 x 130 mm |
|---|---|
| Min. distance between hinges (double-leaf systems) | 1,400 mm |
| Min. distance between hinges with ESR (door coordinator) | 1,450 mm |
| Min. distance between hinges with VARIO Cover | 1,500 mm |
| Operator weight | 12 kg |
| Power supply for external accessories | 24 V DC +/- 10%, 1.5 A |
| Opening angle | Max. 110° |
Inputs and Outputs
Inputs
| Connections | Max. 1.5 mm² |
|---|---|
| Potential-free activator | Inside and outside (NO contact) |
| Night-/Bank (intercom system) | 8 - 24 V DC / AC + 10% |
| Night-/Bank (key switch) | NO contact / NC contact |
| Safety sensor | Hinge side and opposite hinge side (NC contact) |
| Test signal for safety sensor | Hinge side and opposite hinge side |
| Deactivation of operator function (lock switch) | NC contact / NO contact |
Outputs
| Connections | Max. 1.5 mm² |
|---|---|
| Potential-free status indicator |
|
Integrated Functions
| Function | Description/Value |
|---|---|
| Latching action | Force adjustable |
| Hold-open time | 0 - 30 seconds |
| Night-/Bank hold-open time | 0 - 30 seconds |
| Blocking behaviour during closing cycle | Reversing / Door closer function |
| Delayed opening for locking mechanism (electric strike) | 0 - 1 second/s |
| Locking feedback contact | Motor lock |
| Wind load control | Up to 150 N |
| Voltage-independent braking circuit | Adjustable via potentiometer |
| LED status indicator |
|
| Integrated program switch | OFF, AUTOMATIC, PERMANENT OPEN, EXIT ONLY (single-leaf only) |
| User interface | With information display (Status indicator and parameterisation) |
| Slot for DORMA Upgrade Cards | Extension of functional range |
| Update interface | Firmware update |
| TMP | Temperature Management Program (Overload protection) |
| IDC | Initial Drive Control (Driving phase optimisation) |
| Cycle counter | 0 – 1,000,000 (reasonably subdivided) |
| Power Assist Function | Servo-supported manual opening |
| Push & Go Function | The door opens when it is moved manually by 4° |
ED 250 Specific Data
| Max. power consumption | 240 Watts |
|---|---|
| Closing force EN 1154 | EN 4 – 6 continuously adjustable |
| Max. door-leaf weight | 250 kg (lintel depth ≤ 300 mm, width ≤ 1,400 mm) 190 kg (lintel depth ≤ 300 mm, width ≤ 1,600 mm) 160 kg (lintel depth 301-500 mm) |
| Door-leaf width | 700 – 1,600 mm |
| Door-leaf width for fire protection doors | 700 – 1,400 mm |
| Max. opening speed** | 60° (27°*) / second |
| Max. closing speed** | 60° (27°*) / second |
| Axle extension | 30 / 60 / 90 mm |
| Lintel depth for slide channel | +/- 30 mm |
| Lintel depth for standard arm | 0 – 500 mm |
ED 100 Specific Data
| Max. power consumption | 120 Watts |
|---|---|
| Closing force EN 1154 | EN 2 – 4 continuously adjustable |
| Max. door-leaf weight | 100 kg (lintel depth ≤ 300 mm) |
| Door-leaf width | 700 – 1,100 mm |
| Max. opening speed** | 50° (27°*) / second |
| Max. closing speed** | 50° (27°*) / second |
| Axle extension | 30 / 60 mm |
| Lintel depth for slide channel | +/- 30 mm |
| Lintel depth for standard arm | 0 – 300 mm |
* The values in brackets indicate the maximum speed in Low-Energy Mode without Full-Energy or Fire Protection Upgrade Cards.
** Depending on the door-leaf weight automatically limited according to DIN 18650, BS 7036-4 and ANSI 156.19.
Torque Overview
ED 100 Torque
| Values in Nm | Lintel mounting on hinge side with slide channel (Pull-version) | Lintel mounting on opposite hinge side with standard arm (Push-version) | ||
|---|---|---|---|---|
| Min (EN 2) | Max (EN 4) | Min (EN 2) | Max (EN 4) | |
| Closing torque (manually) | 13 | 34 | 13 | 37 |
| Closing torque (Automatic)** | FE: 150 / LE: 67 | FE: 150 / LE: 67 | ||
| Opening torque (manually) | 30 | 50 | 35 | 55 |
| Opening torque (Automatic)** | FE: 150 / LE: 67 | FE: 150 / LE: 67 | ||
| Opening torque of manually-activated Power-Assist Function* | 23 | 23 | ||
ED 250 Torque
| Values in Nm | Lintel mounting on hinge side with slide channel (Pull-version) | Lintel mounting on opposite hinge side with standard arm (Push-version) | ||
|---|---|---|---|---|
| Min (EN 4) | Max (EN 6) | Min (EN 4) | Max (EN 6) | |
| Closing torque (manually) | 26 | 65 | 26 | 70 |
| Closing torque (Automatic)** | FE: 150 / LE: 67 | FE: 150 / LE: 67 | ||
| Opening torque (manually) | 55 | 85 | 60 | 90 |
| Opening torque (Automatic)** | FE: 150 / LE: 67 | FE: 150 / LE: 67 | ||
| Opening torque of manually-activated Power-Assist Function* | 23 | 23 | ||
FE: With Full-Energy or Fire Protection Upgrade Card Full-Energy
LE: Low-Energy basic operator without Upgrade Card
* Power-Assist adjusted to maximum, effective from an opening width of approx. 3°.
** The torque is activated by an automatic opening in AUTOMATIC mode.
Power-Assist Function
The Power-Assist Function may be activated while the door is in door closer mode (parameter Hd = 1). As soon as a user opens the door manually by some degrees, the servo-function supports the manual opening cycle. The servo support automatically adapts to the adjusted size of the door closer.
The level of servo support is adjustable in order to meet the requirements of DIN 18040, DIN Spec 1104, CEN/TR 15894, BS 8300/2100 and document "M", even up to class EN 6.
The smallest adjustable opening torque amounts to 23 Nm/5 lbf., unless the hold-open device is triggered or in the event of a power failure. With the aid of the Power-Assist Function, the system meets the requirements of the European standard EN 1154 and provides barrier-free access during standard operation.