1. General

These operating instructions are intended for the record DFA 127 FP EU or record DFA 127 FP GG EU automatic swing door operator (herein after referred to as DFA 127). The operator is the person responsible for the technical maintenance of this door system.

These instructions describe the use of the record DFA 127 swing door operator. They form the basis for satisfactory functioning.

These operating instructions should be read by the door operator before commissioning and the safety instructions observed!

It is recommended to keep these operating instructions close to the automatic sliding door.

Product designation:
Automatic swing door operator
Product name:
record DFA 127 FP EU or record DFA 127 FP GG EU
Serial number:
(please complete when installing)

2. Safety Instructions

The record DFA 127 swing door operator has been constructed in accordance with the latest state of the art and the recognised technical safety regulations, including limiting of forces and speeds. Nevertheless, danger can arise for the user if not used as intended.

2.1 Use as Intended

The DFA 127 swing door operator is constructed exclusively for normal service with swing doors in dry rooms and must be installed within or inside buildings.

A different application or use extending beyond this purpose is not considered use for the intended purpose. The manufacturer declines all responsibility for resulting damage; the operator alone shall bear the associated risk.

Use for the intended purpose also includes observation of the operating conditions specified by the manufacturer, including use and adjustment of the correct type of arms, in addition to regular maintenance and repair.

Unauthorised modifications to the automatic door operator exclude any liability of the manufacturer for resulting damage.

2.2 General Safety and Accident Prevention Regulations

3. Technical Data

Dimensions:
Operator 600 x 85 x 124 mm (w x h x d)
Operating voltage:
230V~
Power consumption:
Standby 13 W, rated power 67 W
Max. torque:
50 Nm
Opening angle:
Adjustable from 70° to 115°
Time delay:
Adjustable from 0 to 20 seconds
Opening speed:
Adjustable from 3 to 20 seconds
Closing speed:
Adjustable from 5 to 20 seconds
Noise emission:
-18 dB

Environment Conditions

Temperature range:
-15 to +50°C
Humidity range:
Up to 85% relative humidity, non bedewing

3.1 Permissible Door Leaf Weights and Door Widths

The curves are calculated using the following formula:

J = ⅓ × m × b²
Standard arms:
J max. 65 kgm²
Slide arms:
J max. 65 kgm²

Key:

  • J = mass moment of inertia [kgm²]
  • m = door leaf weight [kg]
  • b = door leaf width [m]