9. Drive identification plate

Note: Only relevant in Germany and in the scope of validity of DIN 18650-1:2010-06.

Supplement classification code on the identification plate

GEZE GmbH
Reinhold-Vöster-Str. 21-29
DE-71229 Leonberg
Slimdrive SL NT

Product identification data
12345
876
Date of manufacture
07/2021
Environmental Conditions
Dry areas only
Ambient temperature: 50 °C to -15 °C
Compliance
DIN18650-1:2010-06
Code: 2 | 3 | 2 | 0 | _ _ _ | 0 | _ _ _ _ | 2
Electrical Data
Input: 230 V 50 Hz 0.65 A
Output: 24 V 1 A
Drive type
Sliding door drive
IP rating
IP20

Safety devices on the drive (fifth character)

A distinction is made between three classes in terms of safety requirements:

  • 1: Force limitation
  • 2: Connection to external safety systems which have been approved by the drive manufacturer
  • 3: Low-energy

Note: Several classes may be marked.

Safety at automatic door system – version/installation (seventh character)

A distinction is made between five classes of safety devices on door leaves:

  • 0: No safety devices
  • 1: With sufficiently dimensioned safety distances
  • 2: With protection against crushing, shearing and drawing-in of fingers
  • 3: With built-in turning fitting unit
  • 4: With sensor-controlled protective devices

Note: Several classes may be marked.

Legend:
  1. Product name
  2. Serial number
  3. Electr. data
  4. Machine category
  5. Ambient temperature
  6. Only relevant in Germany and in the scope of validity of DIN 18650-1:2010-06: Classification code
  7. IP rating
  8. Date of manufacture

Slimdrive SL NT product family

10. Inspection of the installed door system (Page 34)

10.1 Protective measures to prevent and protect from hazardous areas

  • Check protective earth connection to all metal parts that can be touched.
  • Perform a safety analysis (risk analysis).
  • Check the function of safety sensors and movement detectors.

Installation checklist Slimdrive SL NT

No. Testing / Item On page Completed
1 All cables laid correctly for the installation of the Slimdrive SL NT?
2 Track mounted? 5.3 (9)
3 Angled floor guide/continuous floor guide installed? 5.4 (10)
4 Moving leaf installed? 5.5 (11)
5 Drive components installed? 5.6.1 (17)
6 Tooth belt mounted? 5.6.2 (17)
7 Closing position for 2-leaf door system set? 5.6.5 (19)
8 Left and right module mounts connected to the power supply? 6.1 (23)
9 Tooth belt locking mechanism (optional) and control unit connected? 5.6.10 (22)
10 Safety devices mounted? 6.3 (27)
11 Switches/push buttons installed and correctly connected? 6.4 (27)
12 Programme switch installed? 6.4 (27)
13 Transformer earthing installed? 5.7 (22)
14 Earthing connections established? 6.2.5 (26)
14b 230/115 V connection established? 6.1 (23)
15 Cover earthing connected? 6.2.5 (26)
16 Cover catch mounted? 6.2 (24)
17 Safety analysis carried out?
18 Deviations of the door system checked in accordance with safety analysis?
19 Are all components mounted in accordance with the following instructions:
20 à Pre-mounting instructions Slimdrive SL NT
21 à Installation instructions Slimdrive SL NT – girder section and fixed panel
22 à Installation instructions protective leaf for sliding door drives
23 à Installation instructions safety leaf
24 Drive identification plate supplemented?
Notes:
  • à Only relevant for Germany and in the scope of validity of DIN 18650.
  • à The identification plate may only be attached to the drive when installation has been checked for correct implementation using the checklist in accordance with GEZE specifications.
Previous
GEZE Slimdrive SL NT Service & Troubleshooting Guide
Next
Инструкция по монтажу GEZE Slimdrive SL и SL-FR 2M

Leave a Comment

Your email address will not be published.