News

GEZE ECdrive T2 Service & Maintenance Instructions

9. Type Plate for the Drive

Note: Some details are only relevant in Germany and within the scope of validity of DIN 18650.

Manufacturer Information & Technical Specifications

GEZE GmbH
Reinhold-Vöster-Str. 21-29
DE-71229 Leonberg
Product: ECdrive T2
Type: Sliding door drive
Date of Manufacture 07/2021
Environment Dry areas only
Temperature Range -15 °C to +50 °C
Standard DIN 18650-1:2010-06
Power Input 230 V / 50 Hz / 0.65 A
Power Output 24 V / 1 A
Protection Rating IP20

Classification Code (DIN 18650)

Sample Code: 2 | 3 | 2 | 0 | _ _ _ | 0 | _ _ _ _ | 2

Safety Devices on the Drive (5th Character)

A distinction is made between three classes in terms of safety requirements:

  • 1: Force limitation
  • 2: Connection to external safety systems which have been approved by the drive manufacturer
  • 3: Low-energy

Note: Several classes may be marked.

Safety at Powered Pedestrian Doors (7th Character)

A distinction is made between five classes of safety devices on door leaves:

  • 0: No safety devices
  • 1: With sufficiently dimensioned safety distances
  • 2: With protection against crushing, shearing, and drawing-in of fingers
  • 3: With built-in pivoting fitting unit
  • 4: With sensor-controlled protective devices

Note: Several classes may be marked.

Type Plate Legend

  1. Product name
  2. Serial number
  3. Electrical data
  4. Machine category
  5. Ambient temperature
  6. Classification code (DIN 18650)
  7. IP rating
  8. Date of manufacture

10. Inspection of the Installed System

10.1 Measures to prevent or protect hazardous areas

  • Check protective earth connection to all metal parts that can be touched.
  • Perform a safety analysis (risk analysis).
  • Check the function of safety sensors and movement detectors.

Mounting Checklist ECdrive T2

No. Test Step Reference (Chapter/Page) Done
1 All cables routed correctly for installation of the ECdrive T2? --
2 Track mounted? 5.4 / p.10
3 Angled floor guide/continuous floor guide installed? 5.6 / p.11
4 Door leaf with single roller carriage installed? 5.7.1 / p.13
5 Door leaf with double roller carriage installed? 5.7.2 / p.15
6 Drive components installed? 5.8 / p.19
7 Tooth belt mounted? 5.8.2 / p.20
8 Closing position with 2-leaf System adjusted? 5.8.4 / p.21
9 Left and right module mounts connected to the power supply? 6.1 / p.24
10 Tooth belt locking mechanism (optional) and control unit connected? 5.8.9 / p.23
11 Safety devices mounted? 6.3 / p.29
12 Switches/push buttons installed? 6.4 / p.29
13 Programme switch installed? 6.4 / p.29
14 Transformer ground connected? 5.8.10 / p.23
15 Ground connections completed? --
16 230 V connection established? 6.1 / p.24
17 Cover earthing connected? 6.2.5 / p.28
18 Cover fixing mounted? 6.2.2 / p.26
19 Cover securing device mounted? 6.2.4 / p.27
20 Safety devices mounted? 6.3 / p.29
21 Additional switches and push buttons mounted? 6.4 / p.29
23 Safety analysis carried out? --
24 Deviations of the system checked in accordance with safety analysis? --
25 Are all components mounted in accordance with the following instructions: --
26 Pre-installation instructions ECdrive T2 --
27 Installation instructions ECdrive T2 – girder section and side panel --
28 Pre-installation and installation instructions GCtherm - fanlight --
29 Pre-mounting instructions profile system leaves and side panel --
30 Addition to the type plate of the sliding door drive complete? p.37 / 9

Important Note: The type plate may only be attached to the sliding door drive if the assembly is checked for correct implementation according to GEZE specifications and using the check.

Previous
GEZE ECdrive T2 Repair: Roller Carriage & Fuse Replacement
Next
dormakaba ED100/250: Barrier-Free Toilet Upgrade Guide

Leave a Comment

Your email address will not be published.