News

Dorma ES 250 PRO / ES 400 PRO Mounting Instructions

Dorma ES 250 PRO / ES 400 PRO Mounting Instructions - Installation Guide

4.4 Mount the optional side panels

  • Mount the wall connection profiles and the side panels according to the profile system manual.

4.5 Mount the optional anti-static brushes

  • Screw 1 anti-static brush onto each of the carriers.

4.6 Mount the carriers

  • Mount the carriers on the door leaves according to the profile system manual.

4.7 Hook in the door leaf

  1. On all carriers, loosen the 2 screws on the counter rollers. (See Fig. 31)
  2. Press the counter roller on the left screw downward.
  1. Guide the door leaves with the carriers above the track rail into the operator profile. (See Fig. 32)
  2. Swivel the door leaves under the operator.
  3. Place the track rollers on the track profile.
  4. Adjust the counter roller on all carriers so that the wheel assembly is 0.5 mm away from the operator profile.
  • Tighten the screws.
  • Check that the door leaves move easily.

4.8 Mount the floor guides

  • Mount the floor guides according to the accompanying manual.

4.9 Align the door leaves

  1. Loosens the screws on the adjustable brackets. (See Fig. 34)
  2. Align the door leaves by turning the adjusting screws so that the distance between the door leaves and the floor is 6 mm (max. 8 mm), and when the door is closed the center seals are parallel.
  1. Tighten the adjustable brackets on the carrier. (See Fig. 36)
  2. Loosen the screws on the adjustable brackets. (See Fig. 37)
  3. Position the door leaves so that they are aligned and the distance between door leaf and wall/side panel is a maximum of 8 mm. (See Fig. 38)
  4. Screw the adjustable brackets tightly to the door leaf. (See Fig. 39)

4.10 Adjust the opening width

  1. Slide the door leaves to the full opening width.
  2. Push the end stops onto the carriers. (See Fig. 40)
  3. Tighten the end stops to 4 Nm.

4.11 Mount the toothed belt engaging units

4.11.1 On 2-leaf units

  • Screw each toothed belt engaging unit to the carrier on the side of the main closing edge (MCE).

4.11.2 On 1-leaf, left-opening units

  • Screw the toothed belt engaging unit onto the carrier.

4.11.3 On 1-leaf, left-opening units (Space required for protective panel/manual release)

  • Screw the toothed belt engaging unit onto the carrier.

4.11.4 On 1-leaf, right-opening units

  • Screw the toothed belt engaging unit onto the carrier.

4.12 Mount the optional locking device

Mount the locking device according to the accompanying manual.

4.13 Mount the DRIVE UNIT

  1. Remove the protective film from the heat conducting pads. (See Fig. 45)
  2. Loosely screw the hammer head screws in the bracket. (See Fig. 46)
  3. Place the DRIVE UNIT on the threaded bolts on the attachment strip. (See Fig. 47)
  4. Tighten the DRIVE UNIT with the nuts and the hammerhead screw. Do not screw the rightmost nut onto the bolt yet.
  5. Screw the protective conductor onto the right-hand bolt. (See Fig. 48)
  6. Screw the protective conductor onto the track profile.
  7. Stick the protective conductor label onto the track profile.

4.14 Mount the tensioning device

(Refer to next section of manual...)

Previous
Dorma ES 250/400 PRO Mounting Instructions
Next
Dorma ES 250/400 PRO Mounting Guide: Belt & Sensors

Leave a Comment