4.4 Mount the optional side panels
- Mount the wall connection profiles and the side panels according to the profile system manual.
4.5 Mount the optional anti-static brushes
- Screw 1 anti-static brush onto each of the carriers.
4.6 Mount the carriers
- Mount the carriers on the door leaves according to the profile system manual.
4.7 Hook in the door leaf
- On all carriers, loosen the 2 screws on the counter rollers. (See Fig. 31)
- Press the counter roller on the left screw downward.
- Guide the door leaves with the carriers above the track rail into the operator profile. (See Fig. 32)
- Swivel the door leaves under the operator.
- Place the track rollers on the track profile.
- Adjust the counter roller on all carriers so that the wheel assembly is 0.5 mm away from the operator profile.
- Tighten the screws.
- Check that the door leaves move easily.
4.8 Mount the floor guides
- Mount the floor guides according to the accompanying manual.
4.9 Align the door leaves
- Loosens the screws on the adjustable brackets. (See Fig. 34)
- Align the door leaves by turning the adjusting screws so that the distance between the door leaves and the floor is 6 mm (max. 8 mm), and when the door is closed the center seals are parallel.
- Tighten the adjustable brackets on the carrier. (See Fig. 36)
- Loosen the screws on the adjustable brackets. (See Fig. 37)
- Position the door leaves so that they are aligned and the distance between door leaf and wall/side panel is a maximum of 8 mm. (See Fig. 38)
- Screw the adjustable brackets tightly to the door leaf. (See Fig. 39)
4.10 Adjust the opening width
- Slide the door leaves to the full opening width.
- Push the end stops onto the carriers. (See Fig. 40)
- Tighten the end stops to 4 Nm.
4.11 Mount the toothed belt engaging units
4.11.1 On 2-leaf units
- Screw each toothed belt engaging unit to the carrier on the side of the main closing edge (MCE).
4.11.2 On 1-leaf, left-opening units
- Screw the toothed belt engaging unit onto the carrier.
4.11.3 On 1-leaf, left-opening units (Space required for protective panel/manual release)
- Screw the toothed belt engaging unit onto the carrier.
4.11.4 On 1-leaf, right-opening units
- Screw the toothed belt engaging unit onto the carrier.
4.12 Mount the optional locking device
Mount the locking device according to the accompanying manual.
4.13 Mount the DRIVE UNIT
- Remove the protective film from the heat conducting pads. (See Fig. 45)
- Loosely screw the hammer head screws in the bracket. (See Fig. 46)
- Place the DRIVE UNIT on the threaded bolts on the attachment strip. (See Fig. 47)
- Tighten the DRIVE UNIT with the nuts and the hammerhead screw. Do not screw the rightmost nut onto the bolt yet.
- Screw the protective conductor onto the right-hand bolt. (See Fig. 48)
- Screw the protective conductor onto the track profile.
- Stick the protective conductor label onto the track profile.
4.14 Mount the tensioning device
(Refer to next section of manual...)