News

Dorma ED 100/250 Upgrade Cards & Functions Guide

Next section

Next page: →

 

Overview of Dorma ED 100/250 Functions and Upgrade Modules
Function Category Description Availability / Upgrade Required
Automatic Opening
Radar Activation Opening signal in the door zone via radar sensor with pre-set opening speed and door open time. Standard
Extended Door Zone Opening signal in extended door zone (up to 10m). MotionIQ calculates optimum opening/hold-open time based on movement patterns. (Requires M A01 sensor). Requires CAN connection unit
Manual & Remote Access Signal by manual release pushbutton, key switch, remote control, telephone, or speaker systems. Standard
Push-and-Go Opening signal by lightly "tapping" the door leaf. Standard
Access Control Signal via card reader, coding switch, biometric, etc. (Night/Bank function). Standard
Adjustable Opening Speed
Low Energy Up to 27°/sec. (Consider risks according to EN 16005). Standard
Upgrade A / B Up to 60°/sec for faster access. A or B
Opening Modes
Servo-controlled Barrier-free access according to DIN EN 1154 (Power Assist function). Standard
Manual opening Without operator assistance (operator mode: OFF). Standard
Automatic Closing
Closing Speed (Low Energy) Up to 27°/sec. (Consider risks according to EN 16005). Standard
Closing Speed (Fast) Up to 60°/sec. A or B
End Stop Strength Adjustable end stop strength/latching action. Standard
Forces & Control
Wind Load Control Automatically adjustable opening and closing force (max 150 N). Standard
Door Closer Mode Closing via spring without assistance, no reversing on obstacle. Standard
Automatic Mode Closing via spring with assistance; reverses on obstacle detection. Standard
Increased Force Temporarily increased force up to max. 200 N (see SPV function). A and C
Hold-Open Time
Standard Hold-Open Adjustable up to 30 seconds. Standard
Extended Hold-Open Adjustable up to 180 seconds. C
Program Switch Permanent open via program switch. Standard
Pulsed Switch Permanent open via pulsed switch (On/Off, flip-flop function). C
Locking Functions
Manual Locking With mechanical lock (operator is off). Standard
Automatic Locking Used with optional analogue motorised lock, electric strike, or magnet. Standard
DCW® Locking Connection of optional DCW® motorised lock or DCW® door lock. D
Re-locking Automatic re-locking function after power failure. Standard
Safety & Sensors
Door Zone Safeguard Simple safeguarding in case of blocking. Standard
Obstacle Detection With optional sensor system integration. Standard
Operating Units
Internal Switch Integrated in the end cap (Off, Automatic, Permanent Open). Standard
External Switch Mechanical or electrical external program switch. Standard
Digital Control Door Pilot app support. Standard
CAN Program Switch Advanced switch (only available with CAN connection unit). Standard (with HW)
Key Switch ST 32 DCW® key switch: Off, Automatic, Night/bank pulse. D
Remote Control Via TMS-Soft as part of a SafeRoute door system. D
Special Functions
Barrier-free Toilet Pre-configured control unit for motorised lock, status indicators, and switches. E
Fire Protection Disables automatic function/closing via external or integrated RMZ/RZ smoke detection. B
Evacuation (EVAC) In fire event: closes and switches to closer mode + low energy. Access via Power Assist & opening pulse. *Restricted in Germany. B and C
Smoke Pressure (SPV) Allows second parameter level to respond to pressure/air flow changes. (A and C) or (B and C)
Emergency Power Connecting an external or integrated emergency power supply. Standard

Upgrade Cards Key

  • A Full-Energy
  • B Fire Protection
  • C Professional
  • D DCW® (Door Control World)
  • E Barrier-free Toilet

* Note regarding EVAC: In Germany restricted and only permitted in combination as a hold-open system.