Record_STA20 20 Manual Opening & Closing: Emergency Failure Guide

Manual Opening and Closing Guide - System 20 & System 20-200

5.1 Manual opening (without manual unlocking device)

Initial situation: The door is disconnected from the mains, blocked in closed position and locked.
  1. Open the operator casing:
    Note If you pull near the hinges, it will help open the casing.
  2. Swivel out the red holding bar in order to keep the casing in open position.
  3. Disconnect the door from the power supply:
    • The socket is located under the operator casing.
    • Installations with in-built emergency battery: Unscrew additionally the battery fuse (located under the operator casing).

Specific System Instructions

System 20

The locking system is provided with an unlocking lever.

  • Turn the lever clockwise.
  • The door unlocks and can be pushed open by hand.
System 20-200

The locking system is provided with an unlocking pin.

  • By pulling the pin, it unlocks the door.
  • The door unlocks and can be pushed open by hand.
Rod locking mechanism MPV

The locking system is provided with a rope loop.

  • Pull strongly on the rope loop.
  • The door unlocks and can be pushed open by hand.
  • Close the casing with a strong pressure on the area of the hinges.

5.2 Manual closing

Initial situation: Electric power is supplied. Door remains blocked in open position.
Notice Depending on the kind of failure, the procedure for a manual closing will be different. Please follow the steps described below.

5.2.1 Manual closing - step 1

Control Unit Operations
Key/Function Action Description
Manual mode Press key twice
  • Door can be opened or closed by hand
  • Temporary door operation (e.g. in case of low temperature outside)
Locked / Night locking Press additionally the locked key
  • Slide the door by hand to the closed position
  • Door is closed and locked (if applicable)

Note: Inform the service point (telephone number is displayed on the BDE-D).

Notice If the door cannot be moved by hand and locked, please follow the steps described in Step 2.

5.2.2 Manual closing - step 2

If the attempts to close and lock the door described under "step 1" have remained unsuccessful, it indicates a severe failure. Please proceed as follows:

  1. Set the door in manual mode with the control unit (see chapter "Manual closing - step 1").
  2. Open the operator casing (swing open):
    Note If you pull near the hinges, it helps open the casing.
  3. Swivel out the red holding bar in order to keep the casing in open position.
  4. Disconnect the installation from the power supply:
    • The socket is located under the operator casing.
    • Installations with in-built emergency battery: Unscrew additionally the battery fuse (located under the operator casing).
  5. Slide the door by hand to the closed position.

Instruction for Locking

System 20
  • Turn the unlocking lever clockwise and hold it in this position so that the door can close completely.
  • The door will lock as soon as you release the unlocking lever.
System 20-200
  • The door locks if you push in the unlocking pin.
Rod locking mechanism MPV
  • Turn the red button clockwise until you feel resistance and cannot go on turning.
  • Manually check that the door is properly locked.
  • Leaving the building is only possible through a second exit.

Important: Inform the service point (telephone number is displayed on the BDE-D).