Next section
Next page: →4 Overview
4.1 Diagrams
| Number | Type | Name |
|---|---|---|
| 70511-0-001 | Drive drawing | GEZE Slimdrive SL NT, drives |
| 70511-ep01 | Installation diagram | Slimdrive SL NT /-FR, ISO-glass fitting |
| 70511-ep03 | Installation diagram | Slimdrive SL NT /-FR, ISO-glass fitting |
| 70511-ep05 | Installation diagram | Slimdrive SL NT/-FR, IGG-door fitting |
| 70511-ep06 | Installation diagram | Slimdrive SL NT /-FR with GGS |
| 70511-ep07 | Installation diagram | Slimdrive SL NT with protective leaf |
| 70511-ep08 | Installation diagram | Slimdrive SL NT/-FR, wooden leaf |
| 70511-ep13 | Installation diagram | Slimdrive SL NT /-FR, ISO-glass fitting + hook lock |
| 70511-ep16 | Installation diagram | Slimdrive SL NT & Lock A, 2-leaf |
| 70511-ep17 | Installation diagram | Slimdrive SL NT & Lock A, 1-leaf |
| 70511-ep18 | Installation diagram | Slimdrive SL NT /-FR, Lock M, 2-leaf |
| 70511-ep19 | Installation diagram | SL NT /-FR, Lock M, 1-leaf |
| 70511-ep21 | Installation diagram | Slimdrive SL NT /-FR, ISO-glass fitting, Lock M |
| 70504-ep03 | Installation diagram | Floor lock for ISO |
| 70484-ep04 | Installation diagram | Safety leaf for sliding door systems |
| 70511-2-0209 | Component drawing | Track, bespoke, SL NT |
| 70511-2-0231 | Component drawing | Track, drilled, SL NT |
| 70511-2-0281 | Component drawing | Track, bespoke, SL NT 2-leaf, GGS with fixed panels |
| 70511-2-0282 | Component drawing | Track, bespoke, SL NT 1-leaf, left hand slide to open, GGS with fixed panel |
| 70511-2-0283 | Component drawing | Track, bespoke, SL NT 1-leaf, right hand slide to open, GGS with fixed panel |
| 70511-2-0228 | Component drawing | Connecting profile roller carriage |
| 70511-2-0200 | Component drawing | Cover, bespoke, SL NT |
| 70511-1-0107 | Component drawing | Module mount right, DCU1-NT, SL NT |
| 70511-1-0108 | Component drawing | Module mount right, SL NT -FR 2M / -FR DUO |
| 70511-1-0109 | Component drawing | Module mount right, SL NT -FR LL/ -FR RWS |
| 70511-1-0106 | Component drawing | Module mount left SL NT and locking mechanism |
| 70511-1-0117 | Component drawing | Module mount left, SL NT |
| 70715-1-0159 | Assembly group drawing | Continuous floor guide |
| 70715-9-9854 | Installation drawing | ISO leaf Slimdrive SL NT |
| 70715-9-9864 | Installation drawing | ISO leaf, rubber secondary closing edge, Lock M, Slimdrive SL NT |
| 70715-9-9863 | Installation drawing | ISO leaf, rubber secondary closing edge, Lock A, Slimdrive SL NT |
The diagrams are subject to change without notice. Use only the most recent version.
4.2 Tools and Aids
| Tool | Size / Details |
|---|---|
| Tape measure | |
| Marking pen | |
| Torque spanner | |
| Allen key | 2 mm, 2.5 mm, 3 mm, 4 mm, 5 mm, 6 mm |
| Open-ended spanner | 8 mm, 10 mm, 13 mm, 15 mm |
| Ring spanner | 8 mm |
| Screwdriver set | Slotted up to 6 mm, cross-slot PH2 and PZ2 |
| Torx key | Tx 20 (bit insert length at least 110 mm) |
| Side-cutting pliers | |
| Crimping pliers | for cables |
| Wire stripper | |
| Plastic bottle | as tip safeguard |
| Display programme switch / Service terminal | ST220 / GEZEconnects |
4.3 Torques
The torques are given at the respective installation step.
4.4 Components and Assembly Groups
See the ep-drawing for the required installation situation and drive drawings.
5 Installation
- Do not loosen screwed electric protective earth connections.
- Secure workplace against unauthorised entry.
- Always work with a second person.
- Use a stepladder or stepstool.
- Keep inside area of track clean.
5.1 Preparations to be made on-site
Check the preparations made on-site by the customer to ensure proper installation:
- Type and load capacity of the façade construction or suspending frame
- Evenness of the installation surface
- Evenness of the finished floor level
- Cable plan requirements
5.2 Preparing the track
Pre-mounted systems are delivered with attached module mount.
- Remove the module mounts to make it easier to fix the track to the wall.
5.3 Mounting the track
- Protect the running surface from damage.
5.3.1 Mounting the intermediate plates
- Clip the intermediate plates (1) onto the rear of the track.
- Upper row of drill holes for wall installation.
- Lower row of drill holes for the clip of the intermediate plate.
Mounting can also be carried out conversely depending on the building structure (post design). Use the upper row of drill holes for fixing if possible.
5.3.2 Install the track
View from the side
- Determine the installation height of the track (2). Take unevenness of wall and floor into account.
- Align the track horizontally.
- Mark the fastening drill holes (1) (upper row of drill holes on the track).
- Remove the track.
- Drill the holes (1) for fixing.
- Install the brush profile with brush (3).
- Screw the track (2) in place.
- Install the sealing profiles (4).
- Press rubber seal into the draught sealing profiles.
With 1-leaf systems:
- Install the wall strips (5).
5.4 Mounting the floor guide
The selection of floor guide depends on the on-site conditions. One of the following floor guide options must be used. For further information see the respective installation drawing, Chapter 4.1.
5.4.1 Fitting angled floor guide for floor mounting (option)
Angled floor guide with moving leaf left hand slide to open:
- Screw the angled floor guide (6) in place using 2 suitable countersunk screws (1) and (2).
Angled floor guide with moving leaf right hand slide to open:
- Screw the angled floor guide (6) in place using 2 suitable countersunk screws (3) and (2).
Legend:
- Countersunk screw for moving leaf left hand slide to open
- Countersunk screw
- Countersunk screw for moving leaf right hand slide to open
- Outside
- Inside
- Angled floor guide
5.4.2 Adjustable angled floor guide for wall mounting (option)
- Screw the fixing bracket (2) to the fixed panel (1) using two screws (5) (torque 5 Nm).
- Align the moving leaf (6) and thus the adjusting angle (4) and tighten the screw (3) (torque 3 Nm).
- If there is no fixed panel available, mount the floor guide on the wall using suitable attachment material.
5.4.3 Continuous floor guide (option)
- See the component drawing "Continuous floor guide" on how to install the continuous floor guide.
- For further information see the respective installation diagrams, Chapter 4.1.
5.5 Installing the moving leaf
5.5.1 Fit the connecting arm
- Always install the moving leaves together with another person.
The moving leaves are still unsecured and move easily.
- Ensure that the moving leaves are not moved accidentally or by unauthorised persons.
1-leaf
- Slide the clamping plate (1) into the connecting arm (only for 1-leaf doors).
- Slide the roller carriage (2, 4) into the connecting profile (3).
- Secure both roller carriages (2, 4) with 2 setscrews (5) each (torque 3 Nm).
2-leaf
- Secure the roller carriage (towards the secondary closing edge) with setscrews (5) (torque 3 Nm).
- Fasten the second roller carriage (towards the main closing edge) with the two screws for the driver (torque 5 Nm).
- The angled part (7) of the connecting arm must be facing the main closing edge.
5.5.2 Inserting roller carriage into the track
- Insert roller carriage (2) into the track (1).
- Insert the moving leaf mounting aid (3) to secure the roller carriage in the track.
- Slide the track-supporting rollers (4) upwards and tighten slightly using screws (5).
5.5.3 Install the supporting brackets on the moving leaf
The supporting brackets are installed during glazing of the moving leaves. In case of subsequent installation of the supporting brackets, the frames of the moving leaves must be dismantled (see installation instructions for moving leaves).
- See installation drawing for the moving leaf for the position of the supporting brackets (1).
5.5.4 Fitting the moving leaves
The moving leaves are very heavy.
- At least 2 people should work together to set up the moving leaf.
- Use 4 suspension bolts (1) to screw the moving leaf to the roller carriage, do not tighten these yet.
- Remove the moving leaf mounting aid.
5.5.5 Adjusting the moving leaves
The moving leaves are still unsecured and move easily.
- Make sure that the moving leaves are not moved accidentally or by unauthorised persons.
- Observe the applicable standards and guidelines on crushing, shearing and drawing-in spots.
Adjust the parallel position and height of the moving leaves:
- Use the suspension bolts (1) to align the door moving leaves flush. Ensure the same level and parallel closing edges when doing so.
- Loosen the fixing screw for the height adjustment (2) and use the adjustment screw (3) to adjust the moving leaf height.
- 2-leaf: Adjust the height of both moving leaves.
- Tighten the screws (2) (torque 20 Nm).
- Tighten the screws (1) (torque 10 Nm).
- Tighten the screw (3) (torque 5 Nm).
- Note the shearing and pinching spots in accordance with DIN 18650 and DIN EN 16005, see safety analysis and diagrams in Chapter 4.1.
- Make the individual moving leaf move smoothly.
Adjusting the counter-roller:
The counter-roller (4) must have an upper clearance of 0.5 mm to the track (corresponds approximately to the thickness of 4 sheets of copy paper).
- Loosen the screw (5) on the rear of the counter-roller.
- Move the counter-roller until a clearance of approx. 0.5 mm is set.
- Tighten the screw (5) again (torque 10 Nm).
5.5.6 Mounting the short driver
Drivers must not touch any obstacle over the entire travel path. See the drive drawing for the precise position of the driver.
1-leaf:
- Mount the short driver (2) to the clamping plate (3) using 2 screws (1).
- Position the clamping plate (3) and short driver (2) on the connecting arm (see drive drawing for position).
- Tighten the screws (1) (torque 5 Nm).
2-leaf:
- Use 2 screws to screw the short driver (1) through the outer oblong holes to the left roller carriage (2) on the right moving leaf (torque 5 Nm).
5.5.7 Install the long driver (2-leaf)
- Use 2 pre-mounted screws to screw the long driver (1) through the outer oblong holes to the right roller carriage (2) on the left moving leaf (torque 5 Nm).
- Position the moving leaf in the closed position.