WARNING: Risk of fatal injury due to electric shock!
- The electrical system (230 V) may only be connected and disconnected by a professional electrician or specialist electrical technician.
- Carry out mains connection and earth conductor test in accordance with VDE 0100 Part 600.
Installation Steps:
- Remove the sheath of the mains cable on a max. of 40 mm.
- Strip the mains cable based on the following measurements:
- Sheath removal length: 40 mm
- Stripping length: 9 mm
- PE line lead: 10 mm
- Connect the drive to the 230 V mains network.
- Switch on the main switch on the transformer.
- Insert the rechargeable battery connector at the control unit.
- Carry out the production test as described in the wiring diagram "Automatic sliding doors DCU1-NT/DCU1-2M-NT".
6.2 Mounting the cover
WARNING! Risk of injury!
People can be injured when the cover is handled.
- Always make sure two people handle the cover.
- Make sure that the cover is attached along the entire length of the track.
- Release the cover carefully and check whether it has been suspended safely.
- Unscrew the locking pin from the tooth belt locking mechanism (optional).
6.2.1 Mounting the cover fixing
- Regardless of the drive length, one cover fixing must be mounted on each end of the cover, as well as another fixing offset by 100 mm.
- Up to a 3000 mm drive length, a total of seven cover fixings must be mounted.
- Above a 3000 mm drive length, a total of 10 cover fixings must be mounted.
6.2.2 Attaching the cover
- Hook the cover with cover fixing on the track.
Note: The cover may not be swiveled up by more than 90° during opening. See Chapter 7.1.1 on how to remove the cover.
- Swivel the cover downwards and turn it into the threaded pin.
- Place the leaf springs over the cover fixings on the outside: place one leaf spring at each of the outermost of the two cover fixings.
- Screw the locking pin for toothed belt locking (option) in again.
6.2.3 Connecting cover earthing
- Connect the earthing cable of the cover with the second plug-in connection of the device flat plug.
6.3 Mounting the safety devices
For information about connection and parameter setting of the safety sensors, and the inputs and outputs and on commissioning, please refer to the wiring diagram.
- Mount safety and activation equipment.
- Route cables properly in cable ducts.
For electrical installation, see wiring diagram.
6.4 Installing operating elements/switches/push buttons
For electrical installation, see wiring diagram.
- Mount the operating elements so that users cannot stand in the danger zones.
6.5 Commissioning the door system
For information about connection and parameter setting of the safety sensors, and the inputs and outputs and on commissioning, please refer to the wiring diagram.
6.5.1 Creating the log book
- Carry out a safety analysis.
- Record installed options in the safety analysis for the operator.
6.6 Dismantling
WARNING! Risk of injury!
People can be injured when the cover is handled.
- Always make sure two people handle the cover.
- Secure the moving leaves against unintentional movement.
- Disconnect the rechargeable battery.
Note: Dismantling is done in the reverse order of installation.