ED Standard Circuit Board Connections

Overview

The connection options for your dorma ed100 and dorma ed 250 depend on the components selected. If the Upgrade Card DCW® is used, all DCW® components can be connected to the DCW® bus in any topology (4-wire system bus).

Configurations

  • 2-leaf doors
  • 1-leaf doors, barrier-free toilet

Component List

  • 01 Power supply
  • 02 Emergency pushbutton, function: Emergency Off
  • 03 Two-pole-and-earth socket
  • 04 External PGS, mechanical
  • 05 External PGS, electronic
  • 06 Pushbutton, inside
  • 07 Pushbutton, outside
  • 08 CleanSwitch, inside
  • 09 CleanSwitch, outside
  • 10 Lock
  • 11 Radar motion detector, inside
  • 12 Radar motion detector, outside
  • 13 Key switch
  • 14 ED 100/ED 250
  • 15 ED 100/ED 250 with continuous cover
  • 16 RM-ED smoke detector*
  • 17 RM-N smoke detector, opposite hinge side
  • 18 RM-N smoke detector, hinge side
  • 19 Optional manual release pushbutton “Tür zu” (German for “close door”)
  • 20 Red-green-display inside
  • 21 Red-green display outside
  • 22 Door Pilot Interface (Bluetooth)
  • 23 Door Pilot App

* Not necessary with integrated smoke detector

Cable Specifications Referenced

  • NYM 3x1,5 mm²
  • 2x0,8
  • 4x0,8
  • 6x0,8
  • 8x0,8

ED CAN Connection Unit

Overview

The connection options depend on the components selected.

Configurations

  • 1-leaf doors
  • 2-leaf doors

Component List

  • 01 Zuleitung (Power Supply)
  • 02 Notbefehlseinrichtung Funktion: Not-Aus (Emergency command device, Function: Emergency Off)
  • 03 Schuko-Steckdose (Two-pole-and-earth socket)
  • 04 External PGS, mechanical1
  • 05 Pushbutton, inside
  • 06 Pushbutton, outside
  • 07 CleanSwitch, inside
  • 08 CleanSwitch, outside
  • 09 Lock
  • 10 Radar motion detector, inside
  • 11 Radar motion detector, outside
  • 12 Key switch
  • 13 ED 100/ED 250
  • 14 ED 100/ED 250 with continuous cover
  • 15 RM-ED smoke detector2
  • 16 RM-N smoke detector, opposite hinge side
  • 17 RM-N smoke detector, hinge side
  • 18 Optional manual release pushbutton “Tür zu” (German for “close door”)
  • 19 MotionIQ radar sensor M A01

1 Only in combination with the optional ED CAN Multi Adapter