TABEL OF SPECIFICATIONS
Detection Mode: | Presence (typical response time: < 200 ms, max: 500 ms) |
Technology | Active infrared with background analysis Spot: 2” x 2” (typ) Number of spots: max. 24 per curtain Number of curtains: 2 |
Mounting Height | 6’6” – 11’6” Local regulations may impact acceptable mounting height (pedestrian applications only) |
Sensor Temperature Range | -13°F – 131°F 0 – 95% relative humidity, non-condensing LCD screen is operational from 14°F – 131°F. The sensor may still be programmed in colder temperatures, but with the remote control. |
Relay 1 | Electromechanical relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VAC Adjustable hold time: 0.5 – 9 s |
Relay 2 | Solid-state relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 VDC / 30 VAC |
Test/Monitoring Input | Sensitivity: Low: < 1 V, High: > 10 V (max. 30 V) Response time on test request: typical < 5 ms |
Supply Voltage | 12 – 24 VAC ±10% 12 – 30 VDC ±10% To be operated from SELV-compatible power supplies only |
Power Consumption | < 2.5 W |
Noise | < 70 dB |
Degree of Protection | IP54 |
Norm Conformity | ISO 13849 PL + Cat. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) |