Record DFA 127: Technical Parameter & Programming Guide

System DFA 127 Parameter Overview & Programming Guide | Technical Manual

Legend & Definition

This parameter overview shows all possible settings. Depending on drive type and configuration, access may be restricted.

S Programming of slave 1 or slave 2 M Parameter modification via MFT (key) on STG (technical level) D Value will reset after default parameter loading

Order number: [Reference] | Client: [Reference]

Programming by end customer / changes: Date / Initials required

System DFA 127 Configuration (≥ V3.00)

Driving Cycle & Speed

  • Opening Speed: 36 (Speedo)
  • Closing Speed: 20 (Speedo)
  • Opening Angle: DIN: min. 95°
  • Time Delay Open: 0...20s
  • Acceleration: 18 (Speedo)
  • Force when Closing: 10 (Speedo)
  • Final Bang: Disabled, Stronger, Slow

Door Type & Arm Configuration

  • Types of Arms: Standard arm, Sliding pulling, Sliding pushing, Inheader
  • Door Type: Master+Slave, Master only
  • Spring Type: Inverse, 15 (Speedo)
  • Opening Assist: 20 (Speedo)

Operating Profiles (Low Energy/Full)

  • Basic operator: Only one-way / locked / All operation modes
  • Standard: EU, USA, UK, Nordics High, Nordics Low
  • Special: Low Energy, Airport, Brussels, Default 1

Switch / Program Switch Positions

  • 3 Pos. (AUTO): Manual / Automatic / Cont. open
  • 3 Pos. (OFF-A): Automatic / OFF / Cont. open
  • 3 Pos. (OFF-M): Manual / OFF / Cont. open
  • 3 Pos. (Lock-A): Automatic / Locked / Cont. open
  • 4 Positions: Automatic / One-way / Cont. open / Locked

Locking Functions

  • Lock Type: Standard, Locking bolt, Magnet, Pulse
  • Logic: Normally locked, 1way locked, Always locked
  • Interlock: Master Interlock / Slave Interlock
  • VRR Manually: 20 (Speedo)
  • Latch Check: 0 (Speedo)

Sensors & Safety (SIS/Collision)

  • SIS (Side Impact Safety): Enabled, Disabled, AUTO, Without
  • Collision Open: Value 35 (Speedo)
  • Collision Close: Value 5 (Speedo)
  • Fire Alarm: Configurable

Control Panel (BDE) & Language

  • Language: Deutsch, Français, English (US/UK), Español, Nederlands, Danish, Polski, Magyar, Italiano, Czech, Türkçe, Slovenscina
  • Display: Brightness BDE 1/2, Contrast BDE 1/2
  • Mode: Normal, OFF-Mode

Double Leaf Sequence (Master/Slave)

  • Open Sequence: 0 = Simultaneous opening
  • Close Sequence: 0 = Simultaneous closing
  • Overlap: 0 = No overlap

Input/Output & FEM 1 Configuration (≥ V1.10 / ≥ V2.40)

This section covers external modules and programmable inputs/outputs for the STG 127 controller.

Basic I/O & Functions

Standard Inputs

  • Emergency Stop: Disabled / Enabled
  • Closing Button: Disabled / Enabled
  • Push to Actuate: Open / Close trigger

Output Signals

  • Alarm Output: Locked, Closed, Open, Locking error
  • Maint. Signals: Maintenance due, Time exceeded
  • Gong: Signal trigger

FEM 1 / Additional Modules

Note: All outputs CAN be configured according to AUX1x_OUT in FEM 1. Not configurable functions are marked with (*).

Parameter ID Functionality / Module In Use
FEM 0 ... FEM 2 Selection of FEM type installed
AKI / AKA Activation Internal/External (AKI 1, AKA 1, SI 1, SI 2)
Sequential Seq. AKI / AKA, Seq. SSK (Side Screen Safety)
AUX Outputs AUX10_OUT [73/74], AUX11_OUT [76/77], AUX12_OUT [79/80]
AUX13_OUT [82/83], AUX14_OUT [88/89], AUX15_OUT [90/91]
AUX16_OUT [92/93], AUX17_OUT [94/95], AUX18_OUT [96/97]
AUX Inputs AUX10_IN [64/65], AUX11_IN [66/67], AUX12_IN [68/69], AUX13_IN [70/71]

Input/Output Mapping Reference

  • OM: Operation Mode (Automatic, One-way, Locked, Continuous Open, Manual, OFF)
  • SFS: Safety Sensor (IN/OUT)
  • BEA Bodyguard: Supported sensor type
  • Railbeam: Supported sensor type