Legend & Definition
This parameter overview shows all possible settings. Depending on drive type and configuration, access may be restricted.
S Programming of slave 1 or slave 2
M Parameter modification via MFT (key) on STG (technical level)
D Value will reset after default parameter loading
Order number: [Reference] | Client: [Reference]
Programming by end customer / changes: Date / Initials required
System DFA 127 Configuration (≥ V3.00)
Driving Cycle & Speed
- Opening Speed: 36 (Speedo)
- Closing Speed: 20 (Speedo)
- Opening Angle: DIN: min. 95°
- Time Delay Open: 0...20s
- Acceleration: 18 (Speedo)
- Force when Closing: 10 (Speedo)
- Final Bang: Disabled, Stronger, Slow
Door Type & Arm Configuration
- Types of Arms: Standard arm, Sliding pulling, Sliding pushing, Inheader
- Door Type: Master+Slave, Master only
- Spring Type: Inverse, 15 (Speedo)
- Opening Assist: 20 (Speedo)
Operating Profiles (Low Energy/Full)
- Basic operator: Only one-way / locked / All operation modes
- Standard: EU, USA, UK, Nordics High, Nordics Low
- Special: Low Energy, Airport, Brussels, Default 1
Switch / Program Switch Positions
- 3 Pos. (AUTO): Manual / Automatic / Cont. open
- 3 Pos. (OFF-A): Automatic / OFF / Cont. open
- 3 Pos. (OFF-M): Manual / OFF / Cont. open
- 3 Pos. (Lock-A): Automatic / Locked / Cont. open
- 4 Positions: Automatic / One-way / Cont. open / Locked
Locking Functions
- Lock Type: Standard, Locking bolt, Magnet, Pulse
- Logic: Normally locked, 1way locked, Always locked
- Interlock: Master Interlock / Slave Interlock
- VRR Manually: 20 (Speedo)
- Latch Check: 0 (Speedo)
Sensors & Safety (SIS/Collision)
- SIS (Side Impact Safety): Enabled, Disabled, AUTO, Without
- Collision Open: Value 35 (Speedo)
- Collision Close: Value 5 (Speedo)
- Fire Alarm: Configurable
Control Panel (BDE) & Language
- Language: Deutsch, Français, English (US/UK), Español, Nederlands, Danish, Polski, Magyar, Italiano, Czech, Türkçe, Slovenscina
- Display: Brightness BDE 1/2, Contrast BDE 1/2
- Mode: Normal, OFF-Mode
Double Leaf Sequence (Master/Slave)
- Open Sequence: 0 = Simultaneous opening
- Close Sequence: 0 = Simultaneous closing
- Overlap: 0 = No overlap
Input/Output & FEM 1 Configuration (≥ V1.10 / ≥ V2.40)
This section covers external modules and programmable inputs/outputs for the STG 127 controller.
Basic I/O & Functions
Standard Inputs
- Emergency Stop: Disabled / Enabled
- Closing Button: Disabled / Enabled
- Push to Actuate: Open / Close trigger
Output Signals
- Alarm Output: Locked, Closed, Open, Locking error
- Maint. Signals: Maintenance due, Time exceeded
- Gong: Signal trigger
FEM 1 / Additional Modules
Note: All outputs CAN be configured according to AUX1x_OUT in FEM 1. Not configurable functions are marked with (*).
| Parameter ID | Functionality / Module In Use |
|---|---|
| FEM 0 ... FEM 2 | Selection of FEM type installed |
| AKI / AKA | Activation Internal/External (AKI 1, AKA 1, SI 1, SI 2) |
| Sequential | Seq. AKI / AKA, Seq. SSK (Side Screen Safety) |
| AUX Outputs |
AUX10_OUT [73/74], AUX11_OUT [76/77], AUX12_OUT [79/80] AUX13_OUT [82/83], AUX14_OUT [88/89], AUX15_OUT [90/91] AUX16_OUT [92/93], AUX17_OUT [94/95], AUX18_OUT [96/97] |
| AUX Inputs | AUX10_IN [64/65], AUX11_IN [66/67], AUX12_IN [68/69], AUX13_IN [70/71] |
Input/Output Mapping Reference
- OM: Operation Mode (Automatic, One-way, Locked, Continuous Open, Manual, OFF)
- SFS: Safety Sensor (IN/OUT)
- BEA Bodyguard: Supported sensor type
- Railbeam: Supported sensor type