DESCRIPTION
TABEL OF SPECIFICATIONS
1. Safety Instruction | Related parts should be operated under low voltage condition. All installation process and maintenance should be carried out by the supplier. |
2. Installation | 1. Install the sensor. Place the device in the proper position, and remove the burrs completely when processing the cable hole. Open the mounting plate after opening the hole. 2. Connect the signal cable to the power terminal of the automatic door. Green, white: signal output (COMMON), Brown, yellow: power input AC / DC 12V~24V. 3. Remove the outer cover and fix the sensor with screws. 4. Connect the terminal to the sensor. 5. Connect the power supply to the sensor, set the detection range and each function switch in sequence. 6. Close the cover. |
3. Adjustment |
1. Detection Range as below shown: NOTE: Please stand out of the detection range around 10s to ensure the sensor has enough time to finish the self-adjustment. 2. Sensitivity Adjustment: Detection Range MIN: 0.5~0.4M, MAX: 4*2M. Select different detection range by adjusting the sensitivity knob. 3. Adjustment of detection direction: (Adjust Direction of front and back/Left and Right flexibly). Adjusting angle of Plain aerial to get different detection distance and range 30~15*2 range. |
4. Cautions | • Position should be fixed tightly to avoid vibrating. • Sensors should not be placed behind the shield. • Moving object should be avoided. • Fluorescent should be avoided. • Do not touch directly, ESD Protection is necessary. |
5. Troubleshooting |
Symptom: Door & Indicator Lose Failure Cause: Did not get on power. Method: Check cable connection & power supply. Symptom: Door Keeps On Closed and Open Cause: Sensor detected the movement of autodoor; vibration of movement. Method: 1. Increase the antenna installation height. 2. Check the position 3, Reduce the sensitivity. Symptom: Door Does Not Close Cause: 1. Switch of autodoor controller lose failure. 2. Incorrect position 3. Incorrect output of sensor. Method: Check the switch of autodoor controller & setting of output. Symptom: Door Keeps On When It Rains Cause: Sensor detected the actions of rain. Method: Adopt waterproof accessories. |
6. Parameter | Technology: Microwave & microwave processor Frequency: 24.125GHz Transmitting power: <20dB EIRP Launch frequency density: <5m W/cm² Installation Height: 4M(MAX) Installation Angle: 90° degree (lengthways) -30 to +30(lateral) Detection Mode: Motion Min detection speed: 5cm/s Power: <2W(VA) Detection range: 4m*2m(Installation Height 2.2M) Relay output (No initial potential): COM NO Maximum current: 1A Maximum voltage: 42V AC/60V DC Maximum switching power: 42W(AC)/60W(DC) Output time: 2 Second Cable length: 2.5 meters Working temperature: -25°C to +55°C Sheathing material: ABS plastic Power supply: AC/DC 12V+10% (50Hz to 60Hz) SIZE: 120(W)x80(H)x50(D)mm |