DESCRIPTION
TABEL OF SPECIFICATIONS
Detection Mode | |
---|---|
Motion | Minimum detection speed: 2 in/s |
Presence | Typical response time: < 200 ms (max: 500 ms) |
Technology | |
---|---|
Microwave Doppler Radar | Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dBm ERP Transmitter power density: < 5 mW/cm² |
Active Infrared with Background Analysis | Spot size: 2" × 2" (typical) Number of spots: max. 24 per curtain Number of curtains: 2 |
Mounting Height | |
---|---|
6'6" – 11'6" Local regulations may impact acceptable mounting height (pedestrian applications only) |
Sensor Temperature Range | |
---|---|
-13 – 131 °F 0 – 95% relative humidity, non-condensing LCD screen is operational from 14 – 131 °F. The sensor may still be programmed in colder temperatures, but with the remote control. |
Output | |
---|---|
Relay 1 | Electromechanical relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VAC Adjustable hold time: 0.5 – 9 s |
Relay 2 | Solid-state relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 VDC / 30 VAC |
Test/Monitoring Input | |
---|---|
Sensitivity | Low: < 1 V High: > 10 V (max. 30 V) |
Response time on test request | Typical < 5 ms |
Supply Voltage | |
---|---|
12 – 24 VAC ±10% 12 – 30 VDC ±10% To be operated from SELV-compatible power supplies only |
Power Consumption | |
---|---|
< 2.5 W |
Noise | |
---|---|
< 70 dB |
Degree of Protection | |
---|---|
IP54 |
FCC Certification | |
---|---|
FCC | G9B-100606 |
IC | 4680A-100606 |
Compliance | |
---|---|
ISO 13849 PL «C» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) |