{"product_id":"geze-dcu700-battery-for-ecturn-oem-replacement","title":"GEZE ECturn Battery | DCU700 9.2V 650mAh Replacement (131473)","description":"\u003ch2\u003eGEZE ECturn Battery (DCU700) - Replacement Specs \u0026amp; Support\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eGEZE ECturn battery\u003c\/strong\u003e is a dedicated replacement battery pack for the ECturn door operator system, with a clear B2B search fit for \u003cstrong\u003eGEZE DCU700 battery\u003c\/strong\u003e, \u003cstrong\u003eGEZE ECturn replacement unit\u003c\/strong\u003e, and \u003cstrong\u003eGEZE ECturn replacement battery\u003c\/strong\u003e intent.\n  \u003cbr\u003e\n  For buyers who need a fast-match spare part, this page also supports the exact procurement signals around \u003cstrong\u003eGEZE ECturn battery unit\u003c\/strong\u003e and \u003cstrong\u003eGEZE ECturn OEM battery\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Browse the matching series here: \u003ca href=\"https:\/\/doordynamic.com\/collections\/ecturn\"\u003eGEZE ECturn\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Name:\u003c\/strong\u003e ECturn Akku\/Battery (Battery Pack)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ECturn door operator system\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Chemistry:\u003c\/strong\u003e NiMH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 9.2V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 650mAh\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Energy:\u003c\/strong\u003e Approx. 5.98Wh\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Emergency opening and closing backup battery pack\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE marked\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e WEEE symbol (crossed-out wheeled bin) present\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Pre-wired plug connector for quick replacement\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number (P\/N):\u003c\/strong\u003e Barcode present on label; exact digits to be confirmed with close-up image\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Article No.:\u003c\/strong\u003e 131473\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlt Reference:\u003c\/strong\u003e ADS1005\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Reference:\u003c\/strong\u003e GEZE ECturn battery replacement (system-compatible)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Search Intent\u003c\/h3\u003e\n\u003cp\u003e\n  This listing is built for technicians and procurement teams searching for a direct-fit \u003cstrong\u003eGEZE DCU700 battery\u003c\/strong\u003e or a complete \u003cstrong\u003eGEZE ECturn replacement unit\u003c\/strong\u003e.\n  It is also relevant for buyers comparing \u003cstrong\u003eGEZE DCU700 replacement unit\u003c\/strong\u003e options when an existing backup battery needs fast replacement.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECturn battery 9.2V 650mAh\u003c\/strong\u003e - strongest fit signal for purchase intent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGEZE ECturn battery replacement\u003c\/strong\u003e - ideal for urgent maintenance jobs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNiMH ECturn backup battery\u003c\/strong\u003e - technical filter term used by service engineers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECturn emergency opening battery pack\u003c\/strong\u003e - matches emergency function searches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECturn Akku OEM replacement\u003c\/strong\u003e - useful for buyers who need system-compatible parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  View the ECturn range again here: \u003ca href=\"https:\/\/doordynamic.com\/collections\/ecturn\"\u003eGEZE ECturn\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003ch3\u003eTechnical \u0026amp; Troubleshooting Support\u003c\/h3\u003e\n\u003cp\u003e\n  For users searching \u003cstrong\u003eGEZE ECturn battery manual\u003c\/strong\u003e, \u003cstrong\u003eDCU700 wiring diagram\u003c\/strong\u003e, or \u003cstrong\u003eECturn troubleshooting support\u003c\/strong\u003e, the official manual excerpt confirms the following service notes.\n\u003c\/p\u003e\n\n\u003ch3\u003eSafety Warning Before Servicing\u003c\/h3\u003e\n\u003cp\u003e\n  When the rechargeable battery is installed, the drive is \u003cstrong\u003enot de-energized\u003c\/strong\u003e just by switching off the supply voltage.\n  To de-energize the drive safely, use this sequence:\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet operating mode to OFF:\u003c\/strong\u003e Ensure the unit is in OFF mode before touching power connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwitch off main power:\u003c\/strong\u003e Turn off at the power switch, or unplug the earth-pin power plug from mains.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemove battery plug at DCU700 control:\u003c\/strong\u003e Disconnect the rechargeable battery plug from DCU700.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWiring \/ Polarity Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery label:\u003c\/strong\u003e AKKU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage shown in diagram:\u003c\/strong\u003e 19.2V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRD:\u003c\/strong\u003e + (positive)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBK:\u003c\/strong\u003e - (negative)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCharging \u0026amp; Replacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDelivery state:\u003c\/strong\u003e The rechargeable battery is not installed in the drive when delivered.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInitial charging:\u003c\/strong\u003e If the battery is discharged at delivery, operate the drive on on-site voltage supply for at least 24 hours after connection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCharged-state voltage note:\u003c\/strong\u003e 21.6V (with rechargeable battery unplugged).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReplacement interval:\u003c\/strong\u003e Replace the rechargeable battery every 2-3 years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eParameter \/ Function Notes\u003c\/h3\u003e\n\u003cp\u003e\n  For buyers searching \u003cstrong\u003eECturn error code\u003c\/strong\u003e, \u003cstrong\u003eDCU700 parameter code\u003c\/strong\u003e, or \u003cstrong\u003evoltage failure setting\u003c\/strong\u003e, the manual excerpt includes function and parameter references rather than a full alarm-code table.\n\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eMeaning\u003c\/th\u003e\n      \u003cth\u003eTroubleshooting Method\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e16 RC\u003c\/td\u003e\n      \u003ctd\u003eBehavior parameter after failure of supply voltage\u003c\/td\u003e\n      \u003ctd\u003eConfirm the parameter is configured for the required site behavior and door function.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e02 (for 16 RC)\u003c\/td\u003e\n      \u003ctd\u003e“Closing and switched off” mode\u003c\/td\u003e\n      \u003ctd\u003eIf reactivation is needed, confirm 16 RC is set to 02 before testing inputs.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKB \/ FK1 \/ FK2\u003c\/td\u003e\n      \u003ctd\u003eTrigger inputs, including radio channel logic\u003c\/td\u003e\n      \u003ctd\u003eCheck whether the drive reconnects the battery, opens\/closes automatically, then disconnects again.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAfter Power Failure With a Charged Battery\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAfter on-site supply voltage failure, the drive executes the function set by \u003cstrong\u003eparameter 16 RC\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eThen the drive switches itself off by disconnecting the battery connection to preserve battery capacity.\u003c\/li\u003e\n  \u003cli\u003eIf operation mode is NA or AU, the drive can be reactivated via \u003cstrong\u003eKB\u003c\/strong\u003e input or radio channel \u003cstrong\u003eFK2\u003c\/strong\u003e (with 16 RC set to 02).\u003c\/li\u003e\n  \u003cli\u003eIf \u003cstrong\u003eKB \/ FK1 \/ FK2\u003c\/strong\u003e is active, the drive should establish battery connection, open and close the door automatically, and then disconnect the battery connection again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Return to the matching series here: \u003ca href=\"https:\/\/doordynamic.com\/collections\/ecturn\"\u003eGEZE ECturn\u003c\/a\u003e.\n\u003c\/p\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cp\u003e\n  If the reset steps, parameter check, polarity verification, and reactivation flow cannot clear the fault, the battery or related hardware is likely degraded beyond recovery.\n  For uptime-critical sites, the recommended action is to purchase a new replacement unit directly using \u003cstrong\u003eManufacturer Article No. 131473\u003c\/strong\u003e as the primary matching reference.\n\u003c\/p\u003e","brand":"Doordynamic","offers":[{"title":"Default Title","offer_id":67201702953005,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/4448\/1325\/files\/geze-dcu700-battery-ecturn-main.png?v=1785644295","url":"https:\/\/doordynamic.com\/products\/geze-dcu700-battery-for-ecturn-oem-replacement","provider":"Doordynamic","version":"1.0","type":"link"}